Balluff Network Interface ProfiNetâ„¢www.balluff.com 215 IntegrationSwitching IO-Linkdiagnostics on / offIf this function is configured, the IO-Link diagnostics is deactivatedfor all ports and can be reactivated for the desired ports.Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0Port 7Port 6Port 5Port 4Port 3Port 2Port 1Port 0IO-LinkcommunicationBit status for each IO-Link port; feedback indicating whether communicationis established.Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0Port 7Port 6Port 5Port 4Port 3Port 2Port 1Port 0Peripheral error,socketFeedback indicating the port at which an error occurred.Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0Port 7Port 6Port 5Port 4Port 3Port 2Port 1Port 0Short circuitSensor supplyFeedback indicating the port at which there is a sensor supply short circuit.Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0Port 7Port 6Port 5Port 4Port 3Port 2Port 1Port 0Station diagnostics Feedback indicating which fault occurred.Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0IO-Linkshort circuitActuatorWarningActuatorShort circuitSensorvoltageShort circuitExternalerrorRes.US actuatorUS sensorDisplay LED Display functionsBit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0GreenLEDRedLED