13www.balmar.net / Customer Service: +1 (360) 435-6100 x1 / Technical Support: +1 (360) 435-6100 x3Tech Service is available Monday - Friday (8:30am - 7:30pm EST)Programming The Belt Load ManagerThe MC-614 provides the ability to manage regulator field potential, making it possible to govern the horsepower loads placedon the drive belt(s) by the alternator. The Belt Load Manager can also be used to protect the alternator from extraordinaryload created by a battery load that’s too large for the alternator’s capacity. The Belt Load Manager is accessed in the basicprogramming mode, directly after the battery type programming mode. The Belt Load Manager can be accessed at the sametime the battery program is set, or by itself.When activating the programming mode, keep in mind that the regulator will scroll through the basic programming mode threetimes before saving and returning to the operational mode. To adjust the regulator for your battery type:1. Turn on the regulator. If the regulator’s BROWN ignition wire is connected to an oil pressure switch, it may be necessary tostart the engine to activate the regulator.2. If the battery type program has been adjusted, TOUCH/HOLD when entry into the Belt Load Manager is indicated by thebEL display on the regulator’s LED.3. If you don’t wish to adjust the battery programming, TOUCH/HOLD the RED dot when the regulator is activated. RELEASEwhen the Pro display is indicated. The regulator will indicate bA, for battery type, and will cycle to bEL.4. TOUCH/HOLD. The regulator display will indicate b-0 (indicating that the Belt Load Manager is off). Continue to HOLDthe regulator display to scroll through seven settings. Each setting decreases the field potential by approximately sevenpercent.5. RELEASE when the display indicates your desired level of field reduction. The display will cycle to bEL. You can re-activateto change your selection, or wait until the regulator cycles to the next programming mode.6. If no other changes are made to the Belt Load Manager program, the regulator will cycle to the next programming mode.bEL INDICATES ENTRY INTOBELT LOAD MANAGER MODEb-0 INDICATES BLM OFF.b-1 INDICATES BLM SETTING #1.FIELD REDUCTION 5%.b-2 INDICATES BLM SETTING #2.FIELD REDUCTION 10%.b-3 INDICATES BLM SETTING #3.FIELD REDUCTION 15%.b-4 INDICATES BLM SETTING #4.FIELD REDUCTION 20%.b-5 INDICATES BLM SETTING #5.FIELD REDUCTION 25%.b-6 INDICATES BLM SETTING #6.FIELD REDUCTION 30%b-7 INDICATES BLM SETTING #7.FIELD REDUCTION 35%.b-8 INDICATES BLM SETTING #8.FIELD REDUCTION 40%b-9 INDICATES BLM SETTING #9.FIELD REDUCTION 45%Programming For Short or Long Display ModeYou can choose the amount of information displayed on the regulator. The information displayed on the short or long display isdetailed on Page 8 of the manual. To adjust the regulator for short or long display:1. TOUCH/HOLD when entry into the short/long display selector is indicated by dSP on the regulator’s LED.2. The regulator display will indicate codes Sd (for short display) or Ld (for long display).3. RELEASE when the display indicates your desired display mode. The display will cycle to dSP. You can re-activate tochange your selection, or wait until the regulator cycles to the next programming mode.dSP INDICATES ENTRY INTO SHORTOR LONG DISPLAY MODESd INDICATES SHORTDISPLAY MODELd INDICATES LONGDISPLAY MODEProgramming For Alternator Failure Advisory Mode (BDL)The regulator provides a ground signal on the dash lamp terminal when the following conditions occur: low battery voltage(<12.7V), high battery voltage (>15.5V), high battery temperature (<52°C), or high alternator temperature (105°C). Inaddition, the user has the option to send the dash lamp ground in the event that the stator output drops to zero volts. TheRegulator’s Default bdL setting is ON. Monitoring stator output is an optional function which can be turned on or off in the basicprogramming mode. The regulator’s default setting for the bdL mode is ON, meaning that the stator output is being monitored.This function can be used in conjunction with a relay to control a charge indicator lamp.1. To enable or disable the stator monitoring function, activate and hold when the bdL mode is indicated.2. Release when the desired setting is shown. NOTE: Stator wire must be connected to the regulator’s Stator-In terminal touse this function.bdL INDICATES ENTRY INTOALTERNATOR FAILUREADVISORY MODEOFF STATOR OUTPUTMONITORING OFFON STATOR OUTPUTMONITORING ON