3.9 Factory Default SettingsInput Settings RSD1Active AutoType SensorSwitch NoDisplay Settings RSD1View NormalSleep DisabledLock Settings RSD1Locked, Unlocked orOpLockUnlocked3.10 Remote InputUse the remote input to program the RSD1 remotely. Activate remote input using the RSD1 buttons to navigate to the RSD1Input Type menu option.For Active Low, connect the gray input wire to ground (0 V dc), with a remote switch connected between the wire andground. To use the Active High function, configure the sensor for Active High using the buttons on the sensor, then connectthe gray input wire to V+ (12 V dc to 30 V dc). Pulse the remote input according to the diagram and the instructionsprovided in this manual.The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds.Exit remote programming modes by holding the remote input low for > 2 seconds, or waiting for the automatic 60-secondtimeout, or by pressing and holding Escape for 2 seconds. The sensor returns to Run mode without saving any newsettings.1x15x1x1xEnter Export ModeEnter Selection ModeExport configuration slot 1Disable remote inputSet remote input to SRSD1 mode0.04 seconds < T < 0.8 secondsTiming between Pulse groups > 1 secondPulse Timing (T)3x2x Export configuration slot 23x Export configuration slot 34x Export configuration slot 45x Export configuration slot 56x Export configuration slot 6Sensor ModeSet remote input to Sensor mode2xRunModeRSD1 Remote Displaywww.bannerengineering.com - Tel: +1.763.544.3164 13