3.2.5 DetailThe specific details of the remote sensor that was used to import configuration data will be available to review.3.3 Input Menu (RSD1 IN)Use the Input menu to view or changethe:• Input polarity• Remote input detection settingsororGo Back to Parent MenuSelect Menu ItemPress to Save SettingPress and Hold to Go Backto Run ModeActive AutoHi(PNP)Low(NPN)DisableSensorRSD1TypeNoYesSwitchRSD in= Default valueFigure 6. RSD1 Input Menu Map3.3.1 Input ActiveThe Active option sets the remote input polarity.Navigate: MENU > INPUT > ActiveDefault: AutoActive Option DescriptionAuto Automatically set the remote input polarity to the setting of the remote sensorHigh Set the remote input polarity to high/PNPLow Set the remote input polarity to low/NPN3.3.2 Input TypeThe Type option sets the input type.Navigate: Menu > Input > TypeDefault: SensorInput Type DescriptionDisable All remote inputs are ignoredSensor Remote input settings are passed directly to the remote sensor. For sensor remote inputprogramming information, reference the literature specific to the connected sensor.RSD1 Remote input is used to control the export function on the RSD1 and to load new configurations tothe attached sensor. For more information, seeRemote Input on page 13.3.3.3 Input SwitchThe Switch option sets external remote input pulse acceptance.Navigate: MENU > INPUT > SwitchRSD1 Remote Displaywww.bannerengineering.com - Tel: +1.763.544.3164 9