c. Go to Main Menu > System > Communications > Data Export > Output Format and select the StartString, Delimiter, and End String.d. Go to Main Menu > System > Communications > Data Export > Advanced.During the Data and Image export operation the sensor's output channels might become full. This canoccur if the sensor is producing export data (frames) faster than the data can be exported from the device(due to bandwidth limitations) or faster than the client is reading the channel export data.This setting affects how the sensor will behave in this situation.• Select Hold READY to ensure that all frames are transmitted. In this case, the READY signal willremain inactive (sensor is busy) until the new frame has been added to the channel fortransmission. Triggers might be missed during this time.• Select Do not hold READY to cause the sensor to discard the new frame if the channel is full andthus activate the READY signal immediately after the current inspection is complete. In this case,the discarded frames will not be transmitted.3.1.4 Communications Channel PortsThe following are the default Ethernet port settings for the communications channels:• Command Channel — 32200• Data Export — 32100• Image Export — 32000iVu Plus BCR Communications11