Examples>> get history passed\x0D\x0A<< OK\x0D\x0A<< 13\x0D\x0A>> get history startframenumber\x0D\x0A<< OK\x0D\x0A<< 3\x0D\x0A>> do history clear\x0D\x0A<< OK\x0D\x0A5.4.9 Inspection Command GroupCommand Group Item DescriptionGet Inspection Status This status of the most recent inspection either Pass, Fail, or Idle (notriggers).Get Inspection Name The name of the active inspection.Get Inspection FrameNumber The most recent inspection frame number.Get Inspection ExecutionTime The most recent inspection execution time in msec.Examples>> get inspection status\x0D\x0A<< OK\x0D\x0A<< Fail\x0D\x0A>> get inspection executiontime\x0D\x0A<< OK\x0D\x0A<< 37.739\x0D\x0A5.4.10 BCR_INPUT Command GroupCommand Group Item DescriptionGet BCR_INPUT CompareData The Barcode inspection compare data string. This string must start andend with the double quote character. This value can be modified usingthe sensor's touchscreen. This remotely modified value is not persistedto the sensors permanent memory. The 'Save' operation is required topersist this value.Set BCR_INPUT CompareData The Barcode inspection compare data string. This string must start andend with the double quote character. This value can be modified usingthe sensor's touchscreen. This remotely modified value is not persistedto the sensors permanent memory. The 'Save' operation is required topersist this value.Get BCR_INPUT CompareMask The Barcode inspection compare string mask in binary format; that is,masked characters are indicated by a "1" and unmasked characters are"0." Note that the mask character string must match the length of thecompare string. This value can be modified using the sensor'stouchscreen. This remotely modified value is not persisted to thesensors permanent memory. The 'Save' operation is required to persistthis value.iVu Plus BCR Communications25