275. Routine check before daily operation(1) Check the storage of fuel.(2) Check if any leak or damage found on the oil pipe, water hose, vent-pipe andhydraulic parts.(3) Check whether the hydraulic hose storage attain to the regular capacity, the oillevel should be at the middle position between the upper and lower scale marks of oillevel meter.(4) Check if fix or loose found on the wheel bolt and transmission bolt.(5) Check tires air pressure.(6) Check steering and transmission for flexibility and reliability.(7) Check the traveling brakes: The free travel of brake pedal is 40mm, theclearance between the front floor and the pedal should be bigger than 20mm.(8) Check the parking brake: The unload truck can park on the 20% grade ramp,when the parking level is pulled to the bottom.(9) Check the electric system to see whether connect, the connector whether loose,the lights, meter whether work normally.6. Precautions of cooling system(1) Use extreme care when removing the radiator pressure cap. In pressure system,the sudden release of pressure can cause a steam flash which would cause a seriouspersonal injury. Loosen cap slowly to allow steam to escape. After that, tighten capsecurely.(2) Check the radiator coolant reservoir fluid level. It should between FULL andLOW mark. Add the same type coolant to specified level if necessary. The coolant canbe used all the year round.(3) Put the coolant on a safe place and mark “Dangerous Matter” for its poisonous.If swallowed by accident, take the emergency first aid and consult a physicianimmediately.(4) According to variety working condition, periodic wiping away the dirt adhering tothe surface of the radiator is necessary.7. Notes during brake-inOperating the machine under the light load, low speed condition for the first stageof operation of 100 hours. Avoid suddenly speeding and brake. Renew the oil in engineoil pan, transmission, driving axle and hydraulic oil tank after 200 operation hours.