Manual 2100-703Page 32 of 40TABLE 13Electrical SpecificationsModel Rated Volts& PhaseNo.FieldPowerCircuitsSingle Circuit Dual CircuitMinimumCircuitAmpacityMaximumExternalFuse orCkt. Brkr.nFieldPowerWireSizenGroundWire MinimumCircuitAmpacity MaximumExternal Fuseor Ckt. BreakernField PowerWire SizenGroundWire SizeCkt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. BW18HB-A00, A0ZA04A08230/208-11111536572040601286121010W24HB-A00, A0ZA04A08230/208-1111 or 2193960254560108610108 42 25 45 25 8 10 10 10W24HB-B00, B0ZB06 230/208-3 11133115351281210W24HB-C00, C0ZC05 460-3 11815101514121412W30HB-A00, A0ZA05A10230/208-1111 or 224507635608088410108 50 26 50 30 8 10 10 10W30HB-B00, B0ZB05B09230/208-31111833452535451088101010W30HB-C00, C0ZC05C09 C15460-311119172326152025301412101014121010W36HB-A00, A0ZA05A10m A15230/208-1111 or 21 or 22755798440609090864410108853532652606030606610610101010W36HB-B00, B0ZB05B09 B15230/208-3111119364751254050601088610101010W36HB-C00, C0ZC05C09 C15460-3111111192526152525301412101014121010 These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310for power conductor sizing. CAUTION: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay specialattention to note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. Maximum size of the time delay fuse or circuit breaker for protection of field wiring conductors. Maximum KW that can operate with the heat pump on is 9KW. Full heat available during emergency heat mode.m Maximum KW that can operate with the heat pump on is 10KW. Full heat available during emergency heat mode.n Based on 75°copper wire. All wiring must conform to the National Electrical Code and all local codes.IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires inaccordance with the National Electrical Code and all local codes.