4DISCHARGE .................. 4” 125lb Flange, HorizontalLIQUID TEMPERATURE . 104°F (40°C) ContinuousMOTOR HOUSING ........ Cast Iron ASTM A-48, Class 30VOLUTE ......................... Cast Iron ASTM A-48, Class 30SEAL PLATE ................. Cast Iron ASTM A-48, Class 30IMPELLER:Design ...........2 Vane, Open with Pump out vaneson Back side. Dynamicallybalanced, ISO G6.3Material ........ Cast Iron ASTM A-48, Class 30SHAFT............................ 416 Stainless SteelSQUARE RINGS ............ Buna-NDIAPHRAGM ................. Buna-NHARDWARE .................. 300 Series Stainless SteelLIFTING BAIL ................ 304 Stainless SteelPAINT ............................. Air dry enamel, top coat(Epoxy Optional)SEAL Design .......... Double Mechanical in oil filledpressure equalized reservoirMaterial ........ Rotating Faces - CarbonStationary Faces - CeramicElastomer - Buna-NHardware - 300 series stainless steelCORD ENTRY ................ 40 Ft. (12.1m) Cord, Epoxy sealedhousing with secondary pressuregrommet for sealing and strain reliefSPEED ........................... 1150, 1750 & 3450RPM,60Hz (nominal), 1450RPM, 50HzBEARINGS:Upper ............... Single Row, Ball, Oil LubricatedLoad ...... RadialLower ............... Single Row, Ball, Oil LubricatedLoad ...... RadialLife ................... 50,000 HR L10 DesignMOTOR: Design .......... NEMA L, Single phase,NEMA B, Three Phase Torque Curve,Oil Filled, Squirrel Cage InductionWinding ........ Class F, Class H Rated Magnet WireService Factor ........ 1.15SINGLE PHASE ............. Capacitor Start/Capacitor Run.Requires BARNES Starter/PanelWhich includes capacitors andoverload protectionTHREE PHASE .............. 200-240/480, 60Hz is Tri voltagemotor. 380-415, 60Hz Dual voltage.Requires overload protectionto be included in control panel, VFDSuitableMOISTURE SENSOR .... N/O, Requires relay in control panelTEMP. SENSOR ............. N/C, Requires relay in control panelOPTIONAL EQUIPMENT.. Seal Material, Impeller Trims,Additional Cord, Epoxy PaintSECTION: A - PUMP SPECIFICATIONS:4SE-L and 4SEU-L Pump Modelsinches(mm)IMPORTANT !1.) PUMP MAY BE OPERATED “DRY” FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS.2.) THIS PUMP IS APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION II HAZARDOUS LOCATIONS.3.) THIS PUMP IS NOT APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION I HAZARDOUS LOCATIONS.4.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED INACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOTINTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPEDMEDIA IS A COMMON OCCURRENCE.