Operation33Operating Instructions Radiation sensors R3XX4.2.1.2 ParametersThe following overview lists the configurable parameters in the order inwhich they appear on the display when you press the mode button .Password promptBefore you can make any changes to the following parameters, you mustenter the valid password here. The password is changed with the lastparameter in configuration mode.Display CMinimum value 0Maximum value 1999Increment 1Default value 0Emission factorThe emission factor is a measure of the ability of materials to absorb or emitinfrared radiation.The value can be between 0.1 and 1.0. A “full radiator”, for instance, has anemission factor of 1.0, whereas a mirror has an emission factor of 0.1.An emission factor that is set too high will cause the temperature display tobe too low.Display EMinimum value 0.100Maximum value 1.000Increment 0.001Default value 0.950Damping(Calculating the average)A time over which an average is to be calculated is set here. Eachtemperature value that is measured is stored in the memory. Once the fixedtime has passed, the system calculates the average over all values locatedin the memory. This damps the temperature display.The time is set in seconds.Display AMinimum value 0.0Maximum value 999.9Increment 0.1Default value 0.3C 0E 1.000A 0.0