Basic Operation and FeaturesBasler A500k Series 3-11PRELIMINARY3.3.1.3 ExSync, Edge-controlled Mode with Synchronous Timing 2Figure 3-10: ExSync, Edge-controlled Mode - Exposure Start and Stop with Frame Valid HighIf the exposure starts and ends while Frame Valid is high (see Table for values n to y):• The actual start of exposure can be x μs later than the rise of the ExSync signal.• Actual length of exposure time = n μs - y μsA504k/kc A501k/kcn exposure set by ExSyncx 5 μs ... 6 μs 20 ... 26.9 μsy 3 μs 12.8 μsExposureFrameValidFlashOutLineValidExSyncExSync Period300 ns (A501k/kc)20...26.9 μs (A501k/kc)5 ... 6 μs (A504k/kc)44 ns (A504k/kc)