Baumer O200 Series Quick Start Manual
Also see for O200: Instruction manual
Photoelectric sensorsO200Baumer Electric AG - CH-8501 FrauenfeldPhone +41 (0)52 728 1122 - Fax +41 (0)63 739 1144www.baumer.comqTarget ®qTeach ®ENDEFRITESCN07.12.2018 / Version 1.1Xpress ModeRelated ModelsO200 Models with Xpress Teach:O200.G (Background suppression sensors)O200.R (Retro-reflective sensors)O200.S (Smart Reflect Light barriers)O200.T/E (Through beam aensors (E: Receiver)(T: Emitter))More Information related to theseproducts can be found on our website(CAD, Beamcharts, CoC, Drawings, IODDs …)www.baumer.com2How to activate the Teach-In- Place tool as shown right or connectTeach-In wire to +Vs.- Green LED flashes with 2 Hz if tool/Teach-Inis recognized properly.1-Point TeachFactory Reset(only threshold)Teach-In Instruction128Teach-PositionSensing direction+10%*Intensity SignalThresholLED Indication LegendLED onLED fl ashing 1LED fl ashing 2LED fl ashing 8O200.G, Background suppressionsensorsO200.R, Retro-refl ective sensorsO200.T/E, Through beam sensorsLevel 11-Point Teach 1-Point TeachSets the switchpoint at the position ofthe object +10%*Sets the threshold as close to themeasurement valueTeach-In Description Level 1Engl*This value is adjustable by IO-Link. Please check the IO-Link manual available o3421Connection Diagrams- Disconnect power before connecting the sensor.- Voltage supply according UL 1310, Class 2or device shall be protected by an external R/C or listed fuse, rated max.30 VAC/3A or 24 VDC/4APush-Pull &Teach-In /IO-Link*PNPComplementaryNPNComplementaryO200.T,Emitter1 - Brown BN +Vs2 - White WH Teach-In* PNPInvertedNPNInverted n.c.3 - Blue BU 0 V4 - Black BK Push-Pull /IO-Link* PNP NPN Test*Only for models with IO-Link or ext. Teach-InBK (4) output / IO-Link*O2000 VBU (3)BN (1) +V SWH (2) Teach-In* or outputTest: Connect Test to +Vs to deactivate the light emission (O200.T)n.c.: Not connectedModels with IO-LinkSSC1/4: Switching Signal ChannelsMDC: Excess Gain, Intensity or Switch Counter(selectable)Quality: The quality bit signals a weak signalAlarm: The alarm bit signals a problem with theconfiguration or the functionality of the sensorScale: Factor by power of ten, applicable to the value ofthe Measurement Data Channel (MDC)IO-Link Process Data Input16 8 0IntegerT(16) IntegerT(8) 8 bitMeasurementData Channel(MDC)Scale Baumer specific7 6 5 4 3 2 1 0SSC4 Alarm Quality SSC1Available Commands:Teach-in commands, light emission on/off, Find Me (locatingsensor) and moreAvailable Parameters:Switching point, output function, time filters, operation modes,qTeach lock time, teach-mode, LED status indicators,Teach-In method and moreAvailable Additional Data:Switch counter, temperature18ReferenceTolerance*Sensing range, SaLED Indicators Green YellowPower onShort circuitOutput 1 activeOutput 1 signal closeto thresholdTeach-In mode see Teach-In InstructionOperating ModeHzHzHzO200.S, SmartReflect Light barriers Optional Teach-In methods*1-Point Teach Confi gurable via IO-LinkWindow mode (only O200.G)Level 1 / 1-Point Teach:Sets a window of +/- 10%* around theposition of the objectDynamic Teach-In(only O200.G, O200.R)The data aquisition starts immediatelyafter activating Teach-In by qTeach orwire and stops as soon as released.Accepted duration of data aquisition:2 … 15 secThe switchpoint or window is defi ned bythe detected min & max value.Teaches the position of thereference (distance)sch EN3421Connection Diagrams- Disconnect power before connecting the sensor.- Voltage supply according UL 1310, Class 2or device shall be protected by an external R/C or listed fuse, rated max.30 VAC/3A or 24 VDC/4APush-Pull &Teach-In /IO-Link*PNPComplementaryNPNComplementaryO200.T,Emitter1 - Brown BN +Vs2 - White WH Teach-In* PNPInvertedNPNInverted n.c.3 - Blue BU 0 V4 - Black BK Push-Pull /IO-Link* PNP NPN Test*Only for models with IO-Link or ext. Teach-InBK (4) output / IO-Link*O2000 VBU (3)BN (1) +V SWH (2) Teach-In* or outputTest: Connect Test to +Vs to deactivate the light emission (O200.T)n.c.: Not connectedModels with IO-LinkSSC1/4: Switching Signal ChannelsMDC: Excess Gain, Intensity or Switch Counter(selectable)Quality: The quality bit signals a weak signalAlarm: The alarm bit signals a problem with theconfiguration or the functionality of the sensorScale: Factor by power of ten, applicable to the value ofthe Measurement Data Channel (MDC)IO-Link Process Data Input16 8 0IntegerT(16) IntegerT(8) 8 bitMeasurementData Channel(MDC)Scale Baumer specific7 6 5 4 3 2 1 0SSC4 Alarm Quality SSC1Available Commands:Teach-in commands, light emission on/off, Find Me (locatingsensor) and moreAvailable Parameters:Switching point, output function, time filters, operation modes,qTeach lock time, teach-mode, LED status indicators,Teach-In method and moreAvailable Additional Data:Switch counter, temperature18ReferenceTolerance*Sensing range, SaLED Indicators Green YellowPower onShort circuitOutput 1 activeOutput 1 signal closeto thresholdTeach-In mode see Teach-In InstructionOperating ModeHzHzHzO200.S, SmartReflect Light barriers Optional Teach-In methods*1-Point Teach Confi gurable via IO-LinkWindow mode (only O200.G)Level 1 / 1-Point Teach:Sets a window of +/- 10%* around theposition of the objectDynamic Teach-In(only O200.G, O200.R)The data aquisition starts immediatelyafter activating Teach-In by qTeach orwire and stops as soon as released.Accepted duration of data aquisition:2 … 15 secThe switchpoint or window is defi ned bythe detected min & max value.Teaches the position of thereference (distance)sch ENPhotoelectric sensorsO200Baumer Electric AG - CH-8501 FrauenfeldPhone +41 (0)52 728 1122 - Fax +41 (0)63 739 1144www.baumer.comqTarget ®qTeach ®ENDEFRITESCN07.12.2018 / Version 1.1Xpress ModeRelated ModelsO200 Models with Xpress Teach:O200.G (Background suppression sensors)O200.R (Retro-reflective sensors)O200.S (Smart Reflect Light barriers)O200.T/E (Through beam aensors (E: Receiver)(T: Emitter))More Information related to theseproducts can be found on our website(CAD, Beamcharts, CoC, Drawings, IODDs …)www.baumer.comEngl |
Related manuals for Baumer O200
Baumer O200.G Quick Start Manual
Baumer qTarget OT500 Quick Start Manual
Baumer OM70-11200090 Quick Start Manual
Baumer 10158526 Quick Start Manual
Baumer 10142521 Quick Start Manual
Baumer 10140060 Quick Start Manual
Baumer OM70-11112017 Quick Start Manual
Baumer OHDM 16P5651 Quick Start Manual
Baumer OHDM 16N5651 Quick Start Manual
Baumer OM70-11112015 Quick Start Manual
manualsdatabase
Your AI-powered manual search engine