en_BA_OM70_point_line.docx 22/64 Baumer Electric AG6/6/2018 8:28 AM/tof V2.0 ANW_81250853 Frauenfeld, Switzerland4.3 LIVE MONITORThe installation conditions can be checked quickly and easily by displaying the lighting reserve as well as themeasuring frequency.4.3.1 Lighting reserveThis factor specifies by how many times an object may become darker in order to obtain a valid measurementnevertheless. For a valid measurement, a minimum of factor 1 is required.The higher this value is, the shorter the object has to be exposed, which increases the measuring frequency.Below factor 1, the sensor gets too little light back and does not specify any measured value, the alarm outputis active.4.3.2 Measuring frequency in HzDisplays the current measuring frequency in Hz.For more information, see the chapter on measuring frequency, measuring repeat time and response time.LIVE MONITOR321 2475 HzCurrentmeasuringfrequency inHzLighting reserveNOTEFor the fastest response time as well as maximum exposure reserve, the object shouldbe as bright as possible (not shiny).