Troubleshooting Checklist4-8 TroubleshootingTable 4-5 Management System TroubleshootingPossible Causes InstructionCannot access LocalManagement.1. Firmware image fault - refer to Table 4-4.2. Management system fault - refer to Table 4-5.Cannot contact devicethrough in-bandmanagement.1. Management System fault - refer to Table 4-5.2. No link to device - verify all network connections betweennetwork management station and 6E233-49 SmartSwitchare valid and operating.User parameters (IP address,community names, etc.) loston reset or power-up.Device setup fault - refer to Table 4-6.Device is not forwardingtraffic from any port.Device setup fault - refer to Table 4-6.Improper CommunityNames Table.1. Refer to the Local Management User’s Guide forCommunity Names Table setup.2. If the Community Names have been forgotten, refer toSection B.1 for instructions on clearing NVRAM.The 6E233-49 SmartSwitchdoes not have an IP address.1. Refer to the Local Management User’s Guide for IPaddress assignment procedure.2. If the 6E233-49 SmartSwitch is using the IP address of the6C105 chassis, ensure that the module is not inSTANDALONE management mode. The LocalManagement User’s Guide provides instructions on settingthe management mode.The applicable front panelport is disabled.1. Enable port. Refer to the Local Management User’s Guidefor instructions on enabling/disabling ports.2. Port may disabled due to Spanning Tree. Review networkdesign and delete unnecessary loops.Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com