12VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUSEN• Use a plate pipe for stoves of Ø80 mm or Ø100 mm depending on the type of system and with silicone gaskets.• It is forbidden to use metal, fibre cement or aluminium flexible pipes.• For change of direction it is obligatory always to use a union (with angle > 90°) with inspection plug whichenables an easy periodic cleaning of the pipes.• Please assure you that after the cleaning the inspection plugs are sealed with its efficient gasket.• It is forbidden to connect more appliances to the same fume conduit.• It is forbidden to convey in the same fume conduit exhausts from overhanging cooker hoods.• It is forbidden to exhaust flue gases directly from the wall towards the outside and closed spaces also at open top.• It is forbidden to connect any other appliance (wood stoves, cooker hoods, boilers, etc...).• The fume conduit must be placed at a distance of minimum 500 mm from flammable or heat-susceptiblecomponents.9.11 EXAMPLES OF CORRECT INSTALLATIONFig. 11 - Example 1LEGEND Fig. 11 page 121 Insulating material2 Reduction from Ø100 to Ø80 mm3 Inspection plug4 Minimum safety distance = 0,5 mt• Chimney flue installation Ø100/120 mm with an enlarged drilling for pipe transit.Fig. 12 - Example 2LEGEND Fig. 12 page 121 Insulating material2 Inspection plug