31VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUSEN• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".• Check the type of glitch as ALARMS page 38.• Clean the burning pot and start the stove up again with P4 key.13.5 "FAN FAILURE" ALARM"ACTIVE ALARM" "AL 4 - FAN FAILURE": the fume fan is out of order.• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".• Check the type of glitch as ALARMS page 38.• Clean the burning pot and start the stove up again with P4 key.13.6 "FAILED IGNITION" ALARM"ACTIVE ALARM" "AL 5 - FAILED IGNITION": the temperatureis not sufficient for ignition.• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".• Check the type of glitch as ALARMS page 38.• Clean the burning pot and start the stove up again with P4 key.13.7 "NO PELLET" ALARMIf the fume probe registers a temperature at the exhaust lower than the minimum threshold and the displayshows "ACTIVE ALARM" "AL 6 - NO PELLET".• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".• Full the hopper.• Clean the burning pot and start the stove up again with P4 key.13.8 "THERMAL SAFETY" ALARMIn the hopper is installed an automatic thermostat which activates if the temperature excursion exceeds theallowed limits, so avoiding the possibility that the pellet inside the hopper could burn because of overheating."ACTIVE ALARM" "AL 7 - THERMAL SAFETY": the thermostat stops the power supply to the auger.• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and then is in "OFF".• Check the type of glitch as ALARMS page 38.• Unscrew the black cap, press the button and screw the cap again.• Clean the burning pot and start the stove up again with P4 key.13.9 "FAILURE DEPRESS" ALARMTo the boiler is connected a pressostat which control the depression and in some stove models on the fire doorid installed a microswitch which registers the opening."ACTIVE ALARM" "AL 8 - FAILURE DEPRESS": the pressostat and/or fire door which is not correctly closed stops thepower supply to the auger.• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and then is in "OFF".• Check the type of glitch as ALARMS page 38.• Unscrew the black cap, press the button and screw the cap again.• Clean the burning pot and start the stove up again with P4 key.13.10 "DOOR OPEN" ALARMOn the lower part of the fire door is installed a microswitch which detects the opening."ACTIVE ALARM" "AL 9 - DOOR OPEN": it means that the fire door is not correctly closed.• Reset the error pressing P4 key. The stove carries out a "FINAL CLEANING" and "OFF" appears.• Check the type of failure as shown on ALARMS page 38.• Clean the burning pot and start the stove up again pressing P4 key.14 MAINTEINANCE14.1 INTRODUCTIONFor a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.• Fume outlet pipes (fume conduit + chimney flue + chimney pot) must always be cleaned, scrubbed andchecked by an authorized technician in compliance with local regulations, with the instructions of themanufacturer and those of your insurance company.• If there are no local regulations and no instruction from your insurance company, it is necessary to have yourfume pipe, chimney flue and chimney pot cleaned at least once a year.• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets andthe electronical elements checked at least once a year.