INSTRUCTIONAL MANUAL 2750L-P/4500L-P/6000L-PAugust, 2001 Rev. K-81-3.8.8 PROGRAM EXAMPLESTable 3-19 lists some typical CIIL strings. Each one illustrates the versatility in programming which is a feature of thepower source. The strings listed transmit the information with the fewest possible characters. Decimal points need notbe included when followed by zeros. Spaces may not be included anywhere in the string.Table 3-19 SAMPLE PROGRAMMING STRINGSPROGRAM STRINGAll three phase to 115 volts and current limitto 2 amperes and enable external syncFNC ACS :CH00 SET CURL2 SET FREQ400 SET VOLT 115SET SYNI Phase B to 100 volts and current limit to 2ampsFNC ACS :CH02 SET CURL.2E1 SET FREQ4E2 SETVOLT100 To power-up state open relay RST ACS :CH00 Phase B to 90 degrees FNC ACS :CH02 SET PANG90 Freq. to 65.23 Hz FNC ACS :CH00 SET FREQ65.23 All three phases to 2.5 amps average currentlimitFNC ACS :CH00 SET CURL2.5 Phase C current limit to 2 amps average FNC ACS :CH03 SET CURL2 Confidence test CNF For status msg STA Output relay closed CLS :CH00 To measure output voltage only of Phase A FNC ACS VOLT :CH01 Output relay opened OPN :CH00 To measure Freq. FNC ACS FREQ :CH00 FTH FREQ To measure output voltage of all phases FNC ACS VOLT Query time of measurement of voltage FNC ACS VOLT INX VOLT