Section 2. TLX106 Tower Installation2-44. Cut and save a 9 inch piece of 12 AWG ground wire from the 12 footlength provided. Thread the remaining 11 foot ground wire through thetower. Secure all wiring so it does not slip back into the tower or conduit.5. Place the tower cap over the tower end.6. Raise the tower on a still day. Place a washer on top of the two nuts oneach foundation bolt. Taking great care not to damage cables between thetower and conduit, raise the tower and lower it onto the conduit andmounting bolts. Install a washer and nut on each bolt and hand tighten.Check plumb of the tower by placing a level on the north and east sides ofthe lower tower section. Adjust the topmost of the two lower nuts(leveling nut) on each bolt as necessary. When plumb is established, lockthe leveling nut in place by tightening the lowest nut against it. Tightenthe three top nuts with the wrench.12AWG Wire 4AWG CableFIGURE 2.2-1. Raising and Grounding the TLX106 Tower2.3 Tower Grounding2.3.1 Supplied Components(1) 5 foot 4 AWG Ground Cable(1) Copper Ground Lug, Bolt(1) Ground Rod, ClampRefer to Section 1 for components supplied by installer.