Cannon Power Flue | 11Overview1. This appliance MUST be installed by an authorisedservice person only.2. This appliance shall be installed in accordance with themanufacturer’s installation instructions, local gas fittingregulations, municipal building codes, electrical wiringregulations, and AS/NZS 5601.1 the AustralianStandard for Gas Installations.3. Open top of carton and remove accessories (logs,Lift carton up and remove. Remove the four transitscrews fixing the heater to the pallet. Check that theheater is suitable for the gas available. Refer to the datalabel located within the fan chamber (Bottom most areaThis heater is supplied with stand off brackets andinsulation blanket for installation into combustiblematerials. Do not remove any when installing intoa combustible enclosure. Make sure blanket hasnot moved during transit. Insulation blanket shouldbe resting firmly against front fascia prior to affixingto wall.Please dispose of packaging appropriately. Keep awayfrom children.ClearancesFor minimum clearances refer FIG 6 and FIG 7.Note: Ensure that the room air fan opening under theheater is not obstructed.Ensure the minimum clearances to combustible materialsare maintained during installation, including adequatespace for the proper operation and servicing of the heater.For clearances to furniture and curtains refer to warningon page 5.Flue OptionsThe heater is supplied with components to suit ahorizontal flue coming through a wall at the back of theheater. The components include a flue cowl which isdesigned to be fitted to the outside wall with suitablefasteners, a condensate drain tube 2m in length, a clampand flexible flue sealant.flexibility in the manner the exhaust flue and intake air areconnected. The exhaust flue and air intake componentsMUST be fully attached to the heater prior to the heaterbeing fitted into the cavity. It is important to ensure theexhaust gas flue pipe has the ability to drain condensationeither back into the heater or out through the terminal wheninstalled horizontally. The exhaust gas flue pipe must nottrap and collect condensation. This will adversely affectthe performance of the heater.POWER FLUE INSTALLATION INSTRUCTIONSwith fascia removed).FIG 7 Brick Fireplace Opening1000mm MIN TO CEILINGABC300mm MINWhen flueing through the roof, the Extended Flue Kitis required (code FLUEWFX). The maximum lengthof flue pipes that can be used with the Power flueheater is 6.0m.Cavity RequirementsThe cavity must be prepared to accept the heater first. Beforecutting any flue opening in the external wall, the finished floorlevel must be known. This floor level must include any tiling,loose hearth or panels which will support the heater.All clearances shown in FIG 6 - FIG 7 must be adhered to.Note: The appliance must be secured at the front toa vertical face. Where this is difficult due to buildinginaccuracies, limited non-combustible packing may beused to obtain a suitable vertical surface. Method of fixingto finished wall surface (plaster/masonry/brick): suitablefixtures which are able to be easily removed must be used.flue cowl and flue pipes).If heater is going to be installed into an elevated cavity,ensure both flexible pipes, along with condensationhose are fully extended so they remain as straight aspossible when sliding heater into position. Avoidtrapping or kinking flue pipes.Flexible ducting is provided to attach the heater to the fluecowl. The use of this flexible ducting provides for someFIG 6 Note: *In the event that space constraints inhibit the installation process where it is not possible tomaintain a 50mm or 100mm cavity depth clearance for ease of installation these clearances can be reduced,however under AS5601 guidelines a minimum clearance of 25mm to combustibles must be maintained at all times.Fitzroy CanterburyBrick Fireplace Mock FireplaceMin Max Min Max605 mm700 mm538 mm640 mm760 mmNA630 mm730 mm538 mm640 mm760 mmNABrick Fireplace Mock FireplaceMin Max Min Max605 mm700 mm472 mm640 mm760 mmNA630 mm730 mm472 mm640 mm760 mmNAHeight (A)Width (B)588 mm NA 588 mm NA 522 mm NA 522 mm NADepth (C - Vertical Flue*)Depth (C - Horizontal Flue*)