MVX250i E, MVX200i E, MVX200 EDISASSEMBLING121-9 Separation of CVF Unit(1) Detach the Shoe Connector Ass’y. (MVX250i E only)(2) Disconnect the CN891, and detach the ACS-MAIN FPC. (MVX250i E only)(3) Remove three screws (k × 2, h × 1), and then detach the Shoe Base and GND Plate.(4) Turn up the CVF Unit, remove one screw (h × 1), disconnect the CN1501, and demount the CVF Unit.(1) Before using a service part of GND Plate, attach the UL Tape to the position indicated in the figure below.(2) Attach the GND plate to the Shoe Base as illustrated below.k2.5mmMetalM1.73.5mmMetalM1.7hNote on Reassembling (2)Note on Reassembling (1)(2)(3)(2)(3)(4)(4)CVF UnitShoe BaseGND PlateACS-MAIN FPCCN891 CN1501MVX250i E only(4) - hGND PlateShoe Base(3) - h(3) - kMVX250i E onlyGND PlateA surplus part of the ULTape shall be foldedonto the back side.Attach the UL tape before reassembling.AttachmentreferenceUL Tape (9 × 25)(1) Shoe Connector Ass'y(3) - kFig. 9