CHAPTER 3 EXPOSURE SYSTEMCOPYRIGHT © 1999 CANON INC. CANON NP6512/6612/7120/7130/7130F REV.0 AUG. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)3-38Figure 3-347Figure 3-348[1][2][3][4][5]C. Exposure System1. Removing the Scanning Lamp1) Disconnect the power plug.2) Remove the copyboard glass.(See Chapter 7.III.C.1. “Removing theCopyboard Glass.”)3) Holding the middle of the No. 1 mirrormount [1], move the No. 1 mirror mount[1] to the right by about 5 cm.4) Free the harness [3] from the guide [2];then, remove the screw [4], and detach thereflecting plate [5].Caution:Do not hold the reflecting plate.