TipIf your oven is located below your hob,the hob's thermal safety measures forbidthe simultaneous use of the hob and thepyrolysis program of your oven.Your hob is equipped with an anti-overhea-ting safety device.This safety can be activated, for example,when the hob is installed over an oven thatis not sufficiently insulated. If this occurs, aseries of small lines appear in the controlpanel. In this case, we recommend that youincrease the ventilation of your hob by crea-ting an opening in the side of your cabinet(8 cm x 5 cm) and/or that you install theoven insulation kit (reference 75X1652) thatis available from the Post-Sales ServiceDepartment.WarningYou must ensure that the air intakeslocated under your cooking applianceremain clear at all times.For all types of installation, your inductionhob needs proper ventilation.EN611 / INSTALLING YOUR APPLIANCE•• PROPER POSITIONINGYour appliance should be positioned so thatthe plug-in unit is accessible.The distance between the edge of yourappliance and the side and rear walls (or par-titions) must be at least four centimetres (areaA).Your appliance can be easily integrated abovea cabinet, an oven or a build-in-ready house-hold appliance. You must simply ensure thatthe air intakes and air outlets are clear (See"Description of Your Appliance" section).BUILD-INFollow the diagram above.Glue the foam seal underneath your applianceby following the outline of the worktop uponwhich your appliance will rest. This will allowyou to achieve an airtight seal with the work-top.Attach the clips to the hob.*** depending on the model4 cm4 cm4 cm4 cmAventilationspace4444••4411 99009933For models and 80cm, makesure that the cross member ofthe unit does not block theflow of air. If necessary, use abevel.66..44