114.3 OPERATION: WEIGHING, SAMPLING AND COUNTING4.3.1 STANDARD SAMPLING AND COUNTING1. With the scale in any mode...2. Press the SAMPLE key and place on scale the number of pieces indicated ondisplay. (A different sample size may be selected by following procedure below).3. Press the ENTER key. The display will change to count mode and the COUNTindicator will illuminate.4. Add to scale the number of additional pieces to be counted and read the totalcount on display.5. When sampling, if the weight is too small, the display will show "INSUFF. ADDXXXXXX", where XXXXXX is the number of additional pieces required for asufficient sample.6. Add to scale the number of additional parts requested and press the ENTERkey. The display will change to count mode and the COUNT indicator willilluminate.7. Add to scale the additional pieces to be counted and read the total count.4.3.2 ADJUSTING THE SAMPLE QUANTITY1. Press the SAMPLE key.2. Press the SAMPLE key again to step to the next sample quantity. Pressing theSAMPLE key repeatedly will cause the sample quantity to step in multiples of 10from 10 through 250; OR3. Key in the desired sample value via the numeric keypad.4. Place on scale the indicated sample quantity and press the ENTER key. Thedisplay will change to count mode and the COUNT indicator will illuminate.5. Add to or remove from scale pieces to be counted and read the total count.4.3.3 SAMPLING AND COUNTING OUT FROM A CONTAINER1. Place the filled container on the scale platform and press the SAMPLE key.2. Remove the number of pieces shown in the display and press the ENTER key.3. Remove the pieces from the container and read the total number removed.4.3.4 TO DISPLAY WEIGHT1. Press the WEIGHT key. The display will show the gross weight if tare is zero, orthe net weight if tare is non-zero. Either the lb or lb-oz indicator will illuminate.4.3.5 COUNTING WITH INSUFFICIENT SAMPLEIf the weight of a sample is below 0.2 pounds, the message "INSUFF. ADDXXXXXX" will be displayed. Although not recommended, it is possible to overridethis message and proceed with counting by pressing the COUNT key when themessage is displayed. The unit will save the weight per piece and proceed toCOUNT mode.