215.5 - Electrical data - 30HXC + option 6130HXC 080 090 100 110 120 130 140 155 175 190 200 230 260 285 310 345 375Power circuitNominal power supply (Un)* V-ph-Hz 380-3-60Voltage range V 342-418Control circuit supply The control circuit is supplied via the factory-installed transformerNominal operating power input* kW 56 63 69 78 82 91 103 111 123 129 142 166 189 198 223 249 261Nominal operating current drawn* A 114 123 132 146 161 178 198 215 235 257 276 315 352 386 430 469 515Total harmonic distortion*** % 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Max. operating power input** kW 87 96 105 118 130 144 159 172 187 212 223 253 281 318 344 374 424Circuit A** kW - - - - - - - - - - 144 159 187 212 172 187 212Circuit B** kW - - - - - - - - - - 79 94 94 106 172 187 212Max. operating current drawn(Un - 10%)***A 162 178 194 218 242 266 294 319 246 392 412 467 519 588 637 692 784Circuit A*** A - - - - - - - - - - 266 294 346 392 319 346 392Circuit B*** A - - - - - - - - - - 145 173 173 196 319 346 392Maximum operating current drawn(Un)***A 148 162 177 198 220 242 267 290 315 356 374 424 472 534 580 630 712Circuit A*** A - - - - - - - - - - 242 267 315 356 290 315 356Circuit B*** A - - - - - - - - - - 132 157 157 178 290 315 356Maximum starting current,standard unit (Un) †A 189 189 203 229 225 279 313 335 360 417 778 908 955 1113 1062 1112 1291Circuit A*** A - - - - - - - - - - 646 751 798 935 773 798 935Circuit B*** A - - - - - - - - - - 536 641 641 757 773 798 935Max. starting current/max. currentdraw ratio, unit1,28 1,17 1,15 1,16 1,14 1,15 1,17 1,16 1,15 1,17 2,08 2,14 2,03 2,08 1,84 1,77 1,81Max. starting current/max. currentdraw ratio, circuit A - - - - - - - - - - 2.67 2.81 2.54 2.63 2.67 2.54 2.63Max. starting current/max. currentdraw ratio, circuit B - - - - - - - - - 4,06 4,08 4,08 4,25 2,67 2,54 2,63Max. starting current - reducedcurrent start (Un) †A std std std std std std std std std std 592 667 714 836 821 871 1014Circuit A A - - - - - - - - - - 460 510 557 658 532 557 658Circuit B A - - - - - - - - - - 260 330 330 400 532 557 658Max. starting current - red. currentstart/max. current draw ratio, unitstd std std std std std std std std std 1,58 1,57 1,52 1,57 1,42 1,39 1,42Circuit A - - - - - - - - - - 1,90 1,91 1,77 1,85 1,84 1,77 1,85Circuit B - - - - - - - - - - 1,97 2,10 2,10 2,25 1,84 1,77 1,85Three-phase short circuit holdingcurrentkA 25 25 25 25 25 25 25 25 25 25 N/A N/A N/A N/A N/A N/A N/ACircuit A kA - - - - - - - - - - 25 25 25 25 25 25 25Circuit B kA - - - - - - - - - - 15 15 15 15 25 25 25Customer standby capacity, unitor circuit B, for evaporator waterpump connections‡kW 8 8 8 11 11 11 15 15 15 15 15 18 18 30 30 30 30* Based on standardised ARI conditions: Evaporator entering/leaving water temperature 12.2°C and 6.7°C. Condenser entering/leaving water temperature 29.6°C/35°C.** Power input, compressor, at unit operating limits (evaporator water entering/leaving temperature = 15°C/10°C, condenser entering/leaving water temperature =45°C/50°C) and a nominal voltage of 460 V (data given on the unit name plate).*** Maximum unit operating current at maximum unit power input.† Maximum instantaneous starting current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced starting current of the largestcompressor)‡ Current and power inputs not included in the values above.N/A Not applicable