15048-30CC5A/CD5AW060 47,000 TDR — 12.00 — 10.40 48,000 3.26 32,200 2.46 8.0CE3AA060 47,000 TDR — 12.00 — 10.40 48,000 3.60 32,400 2.62 8.0COILS + 58MVP100-20 VARIABLE-SPEED FURNACECC5A/CD5AA060 46,000 TDR — 11.50 — 10.05 48,000 3.46 32,200 2.54 8.0CC5A/CD5AW060 47,000 TDR — 12.00 — 10.40 48,000 3.26 32,200 2.46 8.0CE3AA060 47,000 TDR — 12.00 — 10.40 48,000 3.44 32,200 2.56 8.0CK3BA060 47,000 TDR — 12.50 — 10.80 48,000 3.68 31,800 2.66 8.0CK5A/CK5BA060 47,000 TDR — 12.50 — 10.80 48,000 3.46 32,200 2.54 8.0CK5A/CK5BT060 47,000 TDR — 12.50 — 10.80 48,000 3.68 31,800 2.66 8.0CK5A/CK5BX060 47,000 TDR — 12.00 — 10.55 48,000 3.68 31,800 2.66 8.0COILS + 58MVP120-20 VARIABLE-SPEED FURNACECC5A/CD5AA060 46,000 TDR — 11.50 — 10.05 48,000 3.46 32,200 2.54 8.0CC5A/CD5AW060 47,000 TDR — 12.00 — 10.40 48,000 3.26 32,200 2.46 8.0CE3AA060 47,000 TDR — 12.00 — 10.40 48,000 3.44 32,200 2.56 8.0CK3BA060 47,000 TDR — 12.00 — 10.35 48,000 3.58 32,400 2.60 8.0CK5A/CK5BA060 47,000 TDR — 12.00 — 10.35 48,000 3.58 32,400 2.60 8.0CK5A/CK5BT060 47,000 TDR — 12.00 — 10.35 48,000 3.58 32,400 2.60 8.0CK5A/CK5BX060 47,000 TDR — 12.00 — 10.60 48,000 3.58 32,400 2.60 8.0060-30*FK4DNB006 59,000 TDR&TXV 12.00 — — 10.30 60,000 3.40 39,000 2.46 8.0CC5A/CD5AA060 55,000 NONE — — 11.00 9.45 60,000 2.94 39,000 2.24 7.0CC5A/CD5AW060 57,000 NONE — — 11.40 9.75 60,000 3.08 38,500 2.30 7.4CE3AA060 57,000 NONE — — 11.50 9.75 60,000 3.12 39,000 2.32 7.4CK3BA060 55,000 NONE — — 11.00 9.65 60,000 3.06 39,000 2.30 7.0CK5A/CK5BA060 55,000 NONE — — 11.00 9.65 60,000 3.06 39,000 2.30 7.0CK5A/CK5BT060 55,000 NONE — — 11.00 9.65 60,000 3.06 39,000 2.30 7.0CK5A/CK5BX060 57,000 NONE — — 11.50 9.85 60,000 3.18 39,000 2.36 7.4F(A,B)4BN(F,B,C)060 56,500 TDR 11.00 11.00 — 9.50 60,000 3.22 39,500 2.36 7.5F(A,B)4BN(F,B,C)060 56,500 TDR — 11.20 — 9.50 60,000 3.16 40,000 2.32 7.5FB4BNB070 58,000 TDR — 11.50 — 9.80 60,000 3.30 39,500 2.38 7.7FC4CN(F,B)060 56,500 TDR&TXV 11.20 — — 9.50 60,000 3.16 40,000 2.32 7.5FC4CNB070 58,000 TDR&TXV 11.50 — — 9.80 60,000 3.30 39,500 2.38 7.7FG3AAA060 55,500 NONE — — 11.30 9.60 60,000 3.04 39,000 2.30 7.3COILS + 58CV(A,X)110-22 VARIABLE-SPEED FURNACECC5A/CD5AA060 54,500 TDR — 11.30 — 9.75 60,000 2.96 38,500 2.28 7.2CE3AA060 56,500 TDR — 11.50 — 10.05 60,000 3.16 38,500 2.38 7.5CK3BA060 54,500 TDR — 11.50 — 9.90 60,000 3.28 39,000 2.40 7.5CK5A/CK5BA060 54,500 TDR — 11.50 — 9.90 60,000 3.28 39,000 2.40 7.5CK5A/CK5BT060 54,500 TDR — 11.50 — 9.90 60,000 3.28 39,000 2.40 7.5CK5A/CK5BX060 56,500 TDR — 12.00 — 10.20 60,000 3.30 38,500 2.44 7.5COILS + 58CV(A,X)135-22 VARIABLE-SPEED FURNACECC5A/CD5AA060 54,500 TDR — 11.30 — 9.70 60,000 2.96 38,500 2.28 7.2CC5A/CD5AW060 54,500 TDR — 11.50 — 10.00 60,000 3.14 38,500 2.36 7.5CE3AA060 56,500 TDR — 11.50 — 10.05 60,000 3.16 38,500 2.38 7.5CK3BA060 54,500 TDR — 11.50 — 9.85 60,000 3.28 39,000 2.40 7.5CK5A/CK5BA060 54,500 TDR — 11.50 — 9.85 60,000 3.28 39,000 2.40 7.5CK5A/CK5BT060 54,500 TDR — 11.50 — 9.85 60,000 3.28 39,000 2.40 7.5CK5A/CK5BX060 56,500 TDR — 12.00 — 10.20 60,000 3.30 38,500 2.44 7.5COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACECC5A/CD5AA060 54,500 TDR — 11.50 — 9.80 60,000 2.98 38,500 2.28 7.2CC5A/CD5AW060 54,500 TDR — 11.50 — 10.10 60,000 3.16 38,500 2.36 7.5CE3AA060 56,500 TDR — 11.50 — 10.10 60,000 3.18 38,500 2.38 7.5CK3BA060 54,500 TDR — 11.50 — 9.95 60,000 3.28 38,500 2.42 7.5CK5A/CK5BA060 54,500 TDR — 11.50 — 9.95 60,000 3.28 38,500 2.42 7.5CK5A/CK5BT060 54,500 TDR — 11.50 — 9.95 60,000 3.28 38,500 2.42 7.5CK5A/CK5BX060 56,500 TDR — 12.00 — 10.25 60,000 3.30 38,500 2.44 7.5UNITSIZE-SERIES INDOORUNITARI STANDARD RATINGS*Cooling HeatingTCSeasonal Efficiency SEEREERHigh-Temp Low-Temp SeasonalEfficiencyHSPFFactory-SuppliedEnhance-ment StandardRatingField-SuppliedAccessoryTXV** TXV & TDR** TC COP TC COP* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:Cooling Standard:80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.High-Temperature Heating Standard:70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.Low-Temperature Heating Standard:70°F (21°C) db indoor entering air temperature and 17°F (–8°C) db 15°F (11°C) wb air entering outdoorunit.† Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations aredetermined under DOE computer simulation procedures.‡ Requires hard shutoff TXV; based on computer simulation.** TDR is provided on most Carrier Furnaces.COP — Coefficient of PerformanceHSPF — Heating Seasonal Performance FactorSEER — Seasonal Energy Efficiency RatioTC — Total Capacity (Btuh)TDR — Time-Delay RelayTXV — Thermostatic Expansion ValveCombination ratings continued