– 58 –1) Stop the operation of air-conditioner, anddisconnect the power cord from the ACsupply.2) Remove packed valve cover and Electricparts cover.(2-Screws ∅4 x 10L)3) Remove the cord clamp (2-Screws ∅4 x 16L)and disconnect the connecting cable.4) Remove the upper cabinet (5-Screws ∅4 x 10L)Pulling out upword.5) Remove the front cabinet.(3-Screws ∅4 x 10L)Pull the front right portion toward you, andremove it pulling out upward.1) Perform the common procedure 1.2) Remove the fixing screw and the capacitorband.(1-Screw ∅4 x 10L)3) Disconnect the lead wires.1) Perform the common procedure 1.2) Remove the fixing screw and the capacitorband.(1-Screw ∅4 x 10L)3) Disconnect the lead wires.10-2. Outdoor Unit1 Commonprocedure2 Capacitor forcompressor3 Capacitor forfan motorNo. Part name Procedures RemarksUppercabinetFrontFILE NO. SVM-10036cabinetCapacitorforcompressorCapacitor bandCapacitorScrewsØ4 x10LScrews∅4 x 10Lfor fan motorCord clamp2-Screws Ø4 x10LPacked valve cover2-Screws Ø4 x 16L