Carrier 58MVP Service And Maintenance Manual
Also see for GAS FURNACE 58MVP: Installation, start-up, and operating instructionsUser's information manualUser manualUser's information manualUser's information manual
Fig. 15—Service LabelA99108COMPONENT TESTSTATUS CODE EXAMPLE11 NO FAULT IN RECENT HISTORY DISPLAY - Indicates no faults have occurred within last five cycles.To read recent fault history put setup switch "SW-1" in the "ON" position. To clear recent faulthistory, put setup switch "SW-1" in the "ON" position and jumper thermostat terminals"R", "W/W1", and "Y/Y2" simultaneously until an "11" is flashed.12 BLOWER CALIBRATION LOCKOUT - Indicates RPM calculated for low heat was less than 250 RPMor greater than 1300 RPM on two successive attempts. Auto reset after three hours. Resetpower and refer to fault #44 section.13 LIMIT SWITCH LOCKOUT - Indicates the occurrence of 10 successive limit trips during high heator three successive limit trips during low heat. Auto reset after three hours.Check for: - Improper or misaligned limit and/or limit shield.- Improper high or low heat gas input adjustment.- Stuck high heat solenoid in gas valve.14 IGNITION LOCKOUT - Control will auto-reset after three hours. Refer to #34.21 INVALID MODEL SELECTION - Indicates model plug is missing or incorrect. See wiring diagramfor correct connector jumper location.22 SETUP ERROR - Indicates setup switch "SW-1" or SW-6" is positioned improperly. The followingcombinations will cause the fault.- Thermostat call with "SW-1" "ON".- Thermostat call with "SW-6" "ON".-"SW-1" and "SW-6" both "ON" together.23 INVALID BLOWER AIRFLOW SELECTION - Indicates improper "A/C" or "CF" switch setting. The 042and 14 units can deliver 1-1/2 to 3-1/2 tons A/C and 600 to 1400 CFM for continuous fan. The060 and 20 unit can deliver 2 to 5 tons A/C and 800 to 2000 CFM for continuous fan. If code isflashing unit will default to closest allowable airflow.24 SECONDARY VOLTAGE FUSE IS OPENCheck for: - Short circuit in secondary voltage (24V) wiring.31 HIGH PRESSURE SWITCH FAULT - Indicates high pressure switch is closed at call, or in low heat,or fails to close after call, or opens in high heat.Check for: - Plugged condensate drain.- Water in vent piping, possibly sagging pipe.- Improper pressure switch wiring or pressure switch tubing connections.- Failed or "Out-of-Calibration" pressure switches.32 LOW PRESSURE SWITCH FAULT - Indicates low pressure switch is closed at call, or fails to closeafter call, or opens during operation.Check for: - Plugged condensate drain.- Water in vent piping, possibly sagging pipe.- Improper pressure switch wiring or pressure switch tubing connections.- Failed or "Out-of-Calibration" pressure switches.33 LIMIT OR FLAME ROLL-OUT SWITCH IS OPEN - Indicates the limit, rollout switch or auxiliary limitswitch is open or the unit is operating in high heat only mode due to two successive low heatlimit trips. Check for: - Improper or misaligned limit and/or limit shield.- Improper low heat gas input adjustment.- Stuck high heat solenoid in gas valve.34 IGNITION PROVING FAULT - Control will try three more times before a lockout #14 occurs.Check for: - Gas valve defective or gas valve turned "OFF".- Defective Hot Surface Ignitor - Manual valve shut-off.- Low inlet gas pressure- Green wire MUST be connected to furnace sheet metal.- Proper flame sense microamps (.5 microamps D.C. minimum, 4.0 - 6.0 nominal HIGH HEAT)- Inadequate flame carryover or rough ignition.- Oxide buildup on flame sensor (clean with fine sandpaper.)41 BLOWER OUTSIDE VALID SPEED RANGE - Indicates the blower is not operating at the calculatedRPM. If this fault occurs in conjunction with fault #44 check wiring to motor otherwise refer tothe trouble-shooting guide.42 INDUCER OUTSIDE VALID SPEED RANGE - Indicates the inducer is not operating at thecalculated RPM, or has not started within 10 seconds after a call for heat. Check wiring tomotor otherwise refer to the trouble-shooting guide.43 PRESSURE SWITCH CALIBRATION FAULT - Indicates the low and high pressure switch "make"points during high heat purge are not within the calibration range.Check for: - Plugged condensate drain.- Water in vent piping, possibly sagging pipe.- Improper pressure switch wiring or pressure switch tubing connections.- Failed or "Out of Calibration" pressure switches.44 BLOWER CALIBRATION FAULT - Indicates the calculated blower speed is below 250 or above1300 RPM. Unit will default to low or high heat mode if possible. If this fault occurs in conjunctionwith fault #41 check wiring to motor otherwise refer to the trouble-shooting guide. If this faultoccurs by itself check for undersized ductwork, or excessive static caused by a dirty filter, orclosed registers.= 42 FAULTHUMGRY/Y2W/W1CW2MALFUNCTIONMICROPROCESSORRED LED2EMER HEATRED LED1(2)(4)COUNT THE NO.OF FLASHESGREEN LED4LOW HEATYELLOW LED3HIGH HEAT4321FUSE321OFF321OFF1 2 3 4 5 6 7 8OFFSETUP SW,(SW1-8)EACH OF THE FOLLOWING STATUS CODES IS A TWO DIGIT NUMBER WITH THE FIRST DIGITDETERMINED BY NUMBER OF FLASHES OF THE YELLOW LED AND THE SECOND DIGITDETERMINED BY NUMBER OF FLASHES OF THE GREEN LED.RED LED1 ON Furnace is operating in emergency heat.RED LED2 ON The microprocessor has malfunctioned. To reset: Put setup switch "SW-1" in the "ON"position and jumper thermostat terminals "R", "W/W1", and "Y/Y2" simultaneously withthe door switch pushed in and power to the unit "ON". Disconnect jumper and placesetup switch in the "OFF" position. If LED2 reappears replace main control board.YELLOW LED3 ON Furnace is operating in high heat.GREEN LED4 ON Furnace is operating in low heat.RED LED2 FLASHING Line voltage polarity is reversed.STATUSLED CODESERVICEINDUCER OUTSIDE VALIDSPEED RANGETo initiate the component test sequence, shut "OFF" the room thermostat or disconnect the "R"thermostat lead. Put setup switch "SW-6" in the "ON" position to start the component test sequence.Once initiated the main board will turn "ON" the inducer motor-low speed, inducer motor-high speed,hot surface ignitor, blower motor-low speed, and blower motor-high speed for 15-20 seconds each.When component test is completed one or more of the following codes will flash. Gas Valve andHumidifier will not be turned on.CODE DESCRIPTION11 Indicates inducer and blower motor tested OK. Visual check of hot surface ignitor required.22 SETUP ERROR - Same as code 22 above.41 BLOWER OUTSIDE VALID SPEED RANGE - Indicates blower motor failed test. Check blower, wiring,and control center.42 INDUCER OUTSIDE VALID SPEED RANGE - Indicates inducer motor failed test. Check inducer,wiring and control center.To repeat component test turn setup switch "SW-6" "OFF" and then back "ON". After component test iscompleted put setup switch "SW-6" in the "OFF" position and reconnect the "R" thermostat lead.320624-101 REV. HOM24 VCOUNT THE NO.OF FLASHESDEDEHUM11 |
Related manuals for Carrier GAS FURNACE 58MVP
Carrier 58MVP Service And Maintenance Instructions
Carrier 58MVB Service And Maintenance Instructions
Carrier 100 Series Service And Maintenance Procedures Manual
Carrier 58MCB Service And Maintenance Instruction
Carrier IDEALCOMFORT 58MVC Service And Maintenance Procedures Manual
Carrier 58MCA Service And Maintenance Instructions
Carrier 58MCA Service And Maintenance Instructions
Carrier 58MSA Service And Maintenance Instructions
Carrier 58MCB Service And Maintenance Instructions
Carrier 58MEC Service And Maintenance Instructions
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine