Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Catalog No. 04-53620003-01 Printed in U.S.A. Form 62D-1SO Pg 1 1-09 Replaces: NewUser’s Information ManualNOTE TO INSTALLERThis manual should be left with the equipment owner.Your combination heating/cooling unit is equipped withdirect spark ignition and induced draft power combustionblower.TO LIGHT UNITSee Fig. 1 and 2 for location of gas valve. Refer to Fig. 3while performing the following steps.1. Disable unit operation by using the BACview controller.The BACview controller is shipped in the control boxand can be mounted on the unit or at a remote location.a. On the BACview MAIN screen, press ENTER.The LOGIN screen will be shown.b. Enter the PASSWORD (the default admin pass-word is 1111) and press OK. The DECR and INCRbuttons will appear on the bottom of the screen andthe Shutdown command will flash.c. Press the INCR button, then press the OK button.The unit will stop immediately. Shutdown [ON]will be shown on the main screen.2. Close the field-installed manual gas shutoff valve.3. Turn off the electrical power to the unit using the optionaldisconnect or the field-installed disconnect and lock offusing proper lockout and tag-out procedures.4. Remove the gas section panels.5. Move the switch on the gas valve to the OFF position andwait 5 minutes.NOTE: If this is the first installation of the unit, the gasflue hoods must be installed before operating unit. Thesemust be installed for the unit to run properly.WARNING: If the information in thismanual is not followed exactly, a fire orexplosion may result causing propertydamage, personal injury or loss of life.— Do not store or use gasoline or otherflammable vapors and liquids in thevicinity of this or any other appliance.— WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electrical switch;do not use any phone in yourbuilding.• Immediately call your gas supplierfrom a neighbor’s phone. Follow thegas supplier’s instructions.• If you cannot reach your gas sup-plier, call the fire department.— Installation and service must be per-formed by a qualified installer, serviceagency or the gas supplier.WARNINGImproper installation, adjustment, alteration, ser-vice or maintenance can cause injury or propertydamage. Refer to this manual. For assistance oradditional information consult a qualified installer,service agency, or the gas supplier.WARNINGBefore performing recommended maintenance, be suremain power switch to unit is turned off and lockout tag isinstalled. Electrical shock could cause personal injury.WARNINGBurners will light automatically. Do not attempt to light byhand; personal injury may result.DANGER1. Do not turn off the electrical power to unit withoutfirst turning off the gas supply.2. Before attempting to start the gas heating section,familiarize yourself with all the procedures that mustbe followed.3. Never attempt to manually light the burners on theunit with a match, lighter, or any other flame. If theelectric sparking device fails to light the burners, referto the shutdown procedures, then call your dealer assoon as possible.If you do not follow these instructions exactly, a fire orexplosion may result, causing property damage, injury, orloss of life.62DA,DB,DC,DD07-38Vertical or HorizontalDedicated 100% Outdoor Air Unitwith Optional Gas Heat