T-363 4–244.9 CONTROLLER CONFIGURATION VARIABLESTable 4–4 Controller Configuration VariablesCONFIGURATIONNUMBER TITLE DEFAULT OPTIONCnF01 Bypass Valve Enable In 0-in, 1-outCnF02 Evaporator Fan Speed dS (Dual) 0-single, 1-dualCnF03 Control Sensors FOUr (quad) 0-duAL, 1-quadCnF04 Dehumidification Mode On 0-on, 1-offCnF07 Unit Selection, 20FT/ 40FT/45FT 40ft 0-40ft, 1-20ft, 2- 45ftCnF08 Single Phase/Three Phase Motor 1Ph 0-1phe, 1-3pheCnF10 Two Speed Compressor Logic Out (Single) 0-single, 1-dualCnF11 Defrost Off Selection noOFF 0-noOFF, 1-OFFCnF12 TXV/Solenoid Quench Valve Out (TXV) 0-quench, 1-TXVCnF13 Unloader Out 0-in, 1-outCnF14 Condenser Pressure Control (CPC) In 0-in, 1-outCnF15 Discharge Temperature Sensor Out 0-in, 1-outCnF16 DataCORDER Present On (Yes) 0-off, 1-onCnF17 Discharge Pressure Sensor Out (No) 0-out (No), 1-in (Yes)CnF18 Heater Old (Low Watt) 0-old, 1-new (High Watt)CnF19 Controlled Atmosphere Out (No) 0-out, 1-in (Yes)CnF20 Suction Pressure Sensor Out (No) 0-out, 1-in (Yes)CnF21 Autotransformer Out 0-out, 1-inCnF22 Economy Mode Option OFF 0-off, 1-full, 2-std, 3-custCnF23 Defrost Interval Timer Save Option noSAv 0-no_sav, 1-savCnF24 Enable Long PreTrip Test Series Auto1 0-auto1, 1-auto2, 3-aAuto3CnF25 Enable PreTrip Data Recording rSLtS 0-rSLts, 1-dAtACnF26 Heat Lockout Change Option Set to -10C Set to -5CCnF27 Suction Temperature Display Option Out 0-out, 1-inCnF28 Enable Bulb Mode Option NOr 0-normal, 1-bulbCnF29 Enable Arctic Mode Out 0-out, 1-inCnF30 Compressor Size 41cfm 0-41cfm, 1-37cfmCnF31 Probe Check Option SPEC 0-Std, 1-SpecialCnF32 Enable Single Evaporator Fan Option 2EF0 (dual) 0-dual, 1-single_enableCnF33 Enable Snap Freeze Option OFF 0-off, 1-snapCnF34 Temperature Unit Display bOth (C&F) 0-enable both, 1-F, 2-CCnF35 Enable Humidification Mode 0-OFF 1-onCnF36 SMV Type PWM 0-PWM, 1-Spor, 2-AlcoCnF37 Electronic Temperature Recorder rEtUR 0-return, 1-supp, 2-bothCnF38 Quench Bypass Valve 0-Out 1-inCnF39 Expanded Current Limit Range 0-Out 1-in