324 - PHYSICAL AND ELECTRICAL DATA 61WG/30WG/30WGA4.5 - Electrical data, optional hydraulic moduleThe pumps that are factory-installed in these units have motors with efficiency class IE3. The additional electrical data required(1)is as follows:Motors of fixed-speed hydraulic module pumps, 61WG/30WG/30WGA (options 116T and 270T)No.(2) Description(3) 61WG/30WG/30WGA - options 116T and 270T (low-pressure pumps)20 25 30 35 40 45 50 60 70 80 901Nominal efficiency at full load and nominal voltage % 81,1 81,1 81,1 81,1 81,1 81,1 81,1 81,1 81,1 81,1 83,4Nominal efficiency at 75% rated load and nominal voltage % 80,8 80,8 80,8 80,8 80,8 80,8 80,8 80,8 80,8 80,8 81,2Nominal efficiency at 50% rated load and nominal voltage % 77,5 77,5 77,5 77,5 77,5 77,5 77,5 77,5 77,5 77,5 78,32 Efficiency level % IE33 Year of manufacture This information varies depending on the manufacturer and model at thetime of incorporation.Please refer to the motor name plates.4 Manufacturer's name and trademark, commercialregistration number and place of manufacturer5 Product's model number6 Number of motor poles 2 2 2 2 2 2 2 2 2 2 27-1 Rated shaft power output at full load and nominal voltage(400 V) kW 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 1,37-2 Maximum power input (400 V)(4) kW 1,1 1,1 1,1 1,1 1,1 1,1 1,1 1,1 1,1 1,1 1,68 Rated input frequency Hz 50 50 50 50 50 50 50 50 50 50 509-1 Rated voltage V 3x4009-2 Maximum current drawn (400 V)(5) A 2,1 2,1 2,1 2,1 2,1 2,1 2,1 2,1 2,1 2,1 2,910 Rated speed r/s 2850 2850 2850 2850 2850 2850 2850 2850 2850 2850 2890rpm 47 47 47 47 47 47 47 47 47 47 4811 Product disassembly, recycling or disposal at end of life Disassembly using standard tools. Disposal and recycling using anappropriate company.12Operating conditions for which the motor is specifically designedI- Altitudes above sea level m < 1000(6)II - Ambient air temperature °C < 40IV - Maximum air temperature Please refer to the operating conditions given in this manual or in thespecific conditions in the Carrier selection programs.V - Potentially explosive atmospheres Non-ATEX environmentMotors of variable-speed hydraulic module pumps, 61WG/30WG/30WGA (options 116V and 270V)No.(2) Description(3) 61WG/30WG/30WGA - options 116V and 270V (high-pressure pumps)20 25 30 35 40 45 50 60 70 80 901Nominal efficiency at full load and nominal voltage % 83,4 83,4 83,4 83,4 83,4 83,4 84,8 84,8 84,8 84,8 84,8Nominal efficiency at 75% rated load and nominal voltage % 81,2 81,2 81,2 81,2 81,2 81,2 82,2 82,2 82,2 82,2 82,2Nominal efficiency at 50% rated load and nominal voltage % 78,3 78,3 78,3 78,3 78,3 78,3 79 79 79 79 792 Efficiency level % IE33 Year of manufacture This information varies depending on the manufacturer and model at thetime of incorporation.Please refer to the motor name plates.4 Manufacturer's name and trademark, commercialregistration number and place of manufacturer5 Product's model number6 Number of motor poles 2 2 2 2 2 2 2 2 2 2 27-1 Rated shaft power output at full load and nominal voltage(400 V) kW 1,3 1,3 1,3 1,3 1,3 1,3 1,7 1,7 1,7 1,7 1,77-2 Maximum power input (400 V)(4) kW 1,6 1,6 1,6 1,6 1,6 1,6 2,4 2,4 2,4 2,4 2,48 Rated input frequency Hz 50 50 50 50 50 50 50 50 50 50 509-1 Rated voltage V 3x4009-2 Maximum current drawn (400 V)(5) A 2,9 2,9 2,9 2,9 2,9 2,9 4,2 4,2 4,2 4,2 4,210 Rated speed r/s 2890 2890 2890 2890 2890 2890 2870 2870 2870 2870 2870rpm 48 48 48 48 48 48 48 48 48 48 4811 Product disassembly, recycling or disposal at end of life Disassembly using standard tools. Disposal and recycling using anappropriate company.12Operating conditions for which the motor is specifically designedI- Altitudes above sea level m < 1000(6)II - Ambient air temperature °C < 40IV - Maximum air temperature Please refer to the operating conditions given in this manual or in thespecific conditions in the Carrier selection programs.V - Potentially explosive atmospheres Non-ATEX environment(1) Required by regulation 640/2009 with regard to the application of directive 2008/28/EC on the eco-design requirements for electric motors(2) Item number imposed by regulation 640/2009, annex I2b.(3) Description given by regulation 640/2009, annex I2b.(4) To obtain the maximum power input for a unit with hydraulic module add the maximum unit power input from the electrical data table to the pump power input.(5) To obtain the maximum unit operating current draw for a unit with hydraulic module add the maximum unit current draw from the electrical data table to the pump current draw.(6) Above 1000 m, a degradation of 3% for each 500 m should be taken into consideration.