Carrier FZ4ANP Installation Instructions Manual
Installation InstructionsNOTE: Read the entire instruction manual before starting the installation.SAFETY CONSIDERATIONSImproper installation, adjustment, alteration, service, maintenance, oruse can cause explosion, fire, electrical shock, or other conditions whichmay cause death, personal injury or property damage. Consult aqualified installer, service agency, or your distributor or branch forinformation or assistance. The qualified installer or agency must usefactory-authorized kits or accessories when modifying this product.Refer to the individual instructions packaged with kits or accessorieswhen installing.Follow all safety codes. Wear safety glasses, protective clothing andwork gloves. Have a fire extinguisher available. Read these instructionsthoroughly and follow all warnings or cautions included in literature andattached to the unit. Consult local building codes and the current editionsof the National Electrical Code (NEC) NFPA 70.In Canada, refer to the current editions of the Canadian Electrical CodeCSA C22.1.Recognize safety information. This is the safety-alert symbol . Whenyou see this symbol on the unit and in instruction manuals, be alert to thepotential for personal injury.Understand the signal words DANGER, WARNING, and CAUTION.These words are used with the safety-alert symbol. DANGER identifiesthe most serious hazards which will result in severe personal injury ordeath. WARNING signifies hazards which could result in personalinjury or death. CAUTION is used to identify unsafe practices whichmay result in minor personal injury or product and property damage.NOTE is used to highlight suggestions which will result in enhancedinstallation, reliability, or operation.INTRODUCTIONFZ4A models are R-410A Fan Coils designed for installation flexibility.These units leave the factory compliant with low leak requirements ofless than 2% cabinet leakage rate at 0.5 inches W.C. and 1.4% cabinetleakage rate at 0.5 inches W.C. when tested in accordance withASHRAE 193 standard.A TXV is used on FZ4ANP(024-061). All FZ4A fan coils use amulti-tap ECM motor for efficiency. These units have be designed forupflow, downflow (kit required), and horizontal orientations, includingmanufactured and mobile home applications.These units require a field supplied air filter, and are designedspecifically for R-410A refrigerant air conditioners and heat pumps asshipped. These units are available for systems of 24,000 through 60,000BTUh nominal cooling capacity. Factory- authorized, field - installedelectric heater packages are available in sizes 5 through 30kW. SeeProduct Data literature for all available accessory kits.HEATER PACKAGESThis unit may or may not be equipped with an electric heater package.For units not equipped with factory-installed heat, a factory-approved,field-installed, UL listed heater package is available from yourequipment supplier. See unit rating plate for a list of factory-approvedheaters. Heaters that are not factory approved could cause damage whichwould not be covered under the equipment warranty. If fan coil containsa factory-installed heater package, minimum circuit ampacity (MCA)and maximum fuse/breaker may be different than units with a same sizefield-installed accessory heater. The difference is not an error and is dueto calculation differences per UL guidelines.INSTALLATIONCHECK EQUIPMENTUnpack unit and move to final location. Remove carton taking care notto damage unit. Inspect equipment for damage prior to installation. Fileclaim with shipping company if shipment is damaged or incomplete.NOTE: If the door gasket is damaged or missing, the unit may not meetthe ASHRAE 193 standard for cabinet air leakage. Contact your supplierand order kit #344994-751.Locate unit rating plate which contains proper installation information.Check rating plate to be sure unit matches job specifications.MOUNT UNITUnit can stand or lie on floor, or hang from ceiling or wall. Allow spacefor wiring, piping, and servicing unit.IMPORTANT: When unit is installed over a finished ceiling and/orliving area, building codes may require a field-supplied secondarycondensate pan to be installed under the entire unit. Some localities mayallow as an alternative, the running of a separate, secondary condensateline. Consult local codes for additional restrictions or precautions.NOTE: Nuisance sweating may occur if the unit is installed in a highhumidity environment with low airflow.UPFLOW INSTALLATIONIf return air is to be ducted through a floor, set unit on floor over openingand use 1/8 to 1/4-in (3 to 6 mm) thick fireproof resilient gasket betweenduct, unit, and floor.Side return is a field option on slope coil models. Cut opening perdimensions (Fig. 1). A field-supplied bottom closure is required.FZ4ANPFAN COILSWARNING!ELECTRICAL OPERATION HAZARDFailure to maintain proper clearances could result in personal injury ordeath.Before installing or servicing unit, always turn off all power to unit.There may be more than 1 disconnect switch. Turn off accessory heaterpower if applicable. Lock out and tag switch with a suitable warninglabel.CAUTION!CUT HAZARDFailure to follow this caution may result in personal injury.Sheet metal parts may have sharp edges or burrs. Use care and wearappropriate protective clothing, safety glasses and gloves whenhandling parts. |
Related manuals for Carrier FZ4ANP
Carrier FZ4A Installation Instructions Manual
Carrier FB4CNP Installation Instructions Manual
Carrier FMC4X Installation Instructions Manual
Carrier FXM4X Installation Instructions Manual
Carrier FEM4X Installation Instructions Manual
Carrier 42CE Installation Instructions Manual
Carrier 42BJ Installation Instructions Manual
Carrier FX4D 019 Installation Instructions Manual
Carrier PF4MNA Installation Instructions Manual
Carrier FX4D Series Installation Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine