FZ4ANP: Installation InstructionsManufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.2A07565Fig. 1 – Slope Coil Unit in Upflow ApplicationA07566Fig. 2 – Slope Coil in Horizontal Left Application (Factory Configuration)DOWNFLOW INSTALLATIONIn this application, field conversion of the evaporator is required usingaccessory downflow kit along with an accessory base kit. Use fireproofresilient gasket, 1/8 to 1/4-in (3 to 6 mm) thick, between duct, unit, andfloor.NOTE: To convert units for downflow applications, refer to InstallationInstructions supplied with kit for proper installation. For slope fan coils,use kit Part No. KFADC0201SLP. For A-coils, use kit Part No.KFADC0401ACL. Use fireproof resilient gasket, 1/8 to 1/4-in (3 to 6mm) thick, between duct, unit, and floor.NOTE: Gasket kit number KFAHD0101SLP is also required for alldownflow applications to maintain low air leak/low sweat performance.HORIZONTAL INSTALLATIONUnits must not be installed with access panels facing up or down. Allother units are factory built for horizontal left installation (Fig. 2 andFig. 3). When suspending unit from ceiling, dimples in casing indicatesuitable location of screws for mounting metal support straps (Fig. 2).For horizontal applications having high return static and humid returnair, the Water Management Kit, KFAHC0125AAA, may need to be usedto assist in water management.A COILUNITSPOWER ENTRYOPTIONSLOW VOLTENTRYOPTIONSFIELD MODIFIEDSIDE RETURNLOCATION FORSLOPE COILUNITS ONLYFIELD SUPPLIEDRETURN PLENUMUPFLOW/DOWNFLOWSECONDARY DRAINUPFLOW/DOWNFLOWPRIMARY DRAINUNIT018, 024025 - 030A12" (305 mm)17" (432 mm)A1.5" (38 mm)2.5"(64 mm)19" (483 mm)FIELD SUPPLIEDSUPPLY DUCTUPFLOW/DOWNFLOWSECONDARY DRAINUPFLOW/DOWNFLOWPRIMARY DRAIN036 19" (483 mm)018 - 048 21" (533 mm) FRONT SERVICE060 - 060 24" (610mm) CLEARANCEUNITFIELDSUPPLIEDHANGINGSTRAPSLOW VOLTENTRYOPTIONSPOWERENTRY OPTIONSSECONDARYDRAIN018-048 21" (533 mm)060-060 24" (610 mm)FRONT SERVICECLEARANCE(FULL FACEOF UNIT)SECONDARYDRAINA-COILHORIZONTAL LEFTPRIMARYDRAINPRIMARYDRAIN1.75" (44 mm)FILTER ACCESSCLEARANCECAUTION!PRODUCT OR PROPERTY DAMAGE HAZARDFailure to follow this warning caution may result in product or propertydamage.The conversion of the fan coil to downflow requires special proceduresfor the condensate drains on both A-coil and Slope-coil units. Thevertical drains have an overflow hole between the primary andsecondary drain holes. This hole is plugged for all applications exceptdownflow, and must be used for downflow. During conversion process,remove plastic cap covering vertical drains only and discard. Removeplug from overflow hole and discard. At completion of downflowinstallation, caulk around vertical pan fitting to door joint to retain lowair leak performance of the unit.