8zones. When finished, press right--side button to continue. See Fig.20.ZONINGSEARCHING FORZONE EQUIPMENTWORKINGZONINGZONE 1 UIZONE 2 RSZONE 3 RSZONE 4 RSUI=USER INTERFACERS=REMOTE SENSORSS=SMART SENSORBACK CONTINUEA04084Fig. 20 -- ZoningEquipment SummaryThe “EQUIPMENT SUMMARY” screen will appear afterAccessories have been selected. This screen will give a summary ofall equipment automatically found or manually selected. If a wrongselection was made, press left--side button (BACK selection) to goback to that particular screen and make changes. When everythingis OK, press right--side button again to continue. (See Fig. 21.)EQUIPMENT SUMMARYFURNACE 58MVB0100-12AC 24ANA136A003FILTER EACHUMIDIFIER YESUV LIGHTS YESZONES 12345678NO YESSETUPCOMPLETE!SAVEALL SELECTIONS/NO YESA07024Fig. 21 -- Equipment SummaryThe “SETUP COMPLETE! SAVE ALL SELECTIONS?” screenwill appear after Equipment Summary. To Save All Selectionspress (YES) right--side button. Pressing the left--side button (NOselection) will return to the Equipment Summary screen wherechanges can be performed to any of the equipment selectionscreens. After selecting YES, the initial power up sequence of thenew Infinity Zone Control is complete.Static Pressure CheckSTATICPRESSURECHECKPLEASE WAITEXTERNAL STATICPRESSUREMEASURED:0.72 INCHESAT 1200 CFMCONTINUE >A05000Fig. 22 -- Static Pressure CheckThis screen will appear after Setup is exited. The system will openall dampers and perform a static pressure check. This process willtake about 1 1/2 minutes to complete. When completed, a screenwill appear displaying the static pressure (in inches) across theequipment at the expected highest delivered airflow. If the staticpressure is over 1 inch, a warning will appear, but equipmentoperation and the TrueSenset dirty filter detection operation willnot be affected.NOTE: The static pressure check occurs only at initial installation,or when INSTALL is run in the INSTALL/SERVICE menu.Duct AssessmentThe following screen will appear after STATIC PRESSURE screenis exited. Press right--side button to start Duct Assessment. DuctAssessment will measure the relative size of the ductwork, up toand through the dampers. These measurements are used to controlthe correct amount of airflow in the zoned system. Status messageswill appear on the screen to indicate what the system is doing. Theprocess will take approximately one minute per zone. The ductassessment will override a call for heat or cool.A duct assessment will automatically occur each day at a userselectable time. The factory default time is 1:00 p.m. but, may bechanged by entering the Zoning Setup menu. See Zoning Setupsection of this manual. The duct assessment will override a call forheat or cool. The system will first open all zones and drive theblower to 175 CFM/ton of cooling (or the minimum indoor unit’sairflow, whichever is greater). It will then take a static pressuremeasurement. The system will then close all zones and open onezone at a time, taking a static pressure measurement for each zone.The system will then close all zones and take a pressuremeasurement, getting a value for the duct leakage up to andthrough the dampers. With these static pressure measurements, thesystem will calculate the relative size of each zone as well as thepercent leakage through the dampers At the end of the process, thedisplay will show the relative size of each zone duct. See Fig. 23.DUCT ASSESSMENTMEASURE DUCTCAPACITY FOR EACHZONE.4 MINUTES ARE REQUIREDTO COMPLETEPRESS START TO BEGINQUIT STARTDUCT ASSESSMENTASSESSMENT ACTIVEPLEASE WAITOPENING ALL ZONESAIRFLOW STABILIZINGPROGRESSSTOPDUCT ASSESSMENTZONE CAPACITYZONE1 25ZONE 2 20ZONE 3 25ZONE 4 20DAMPER LEAKAGE 10QUIT STARTA04085Fig. 23 -- Duct AssessmentQUICK STARTFor first time installers, Quick Start will allow a quick start up ofthe Infinity Zone System before learning all the details of systemoperation. However, for the best possible comfort and operationrefer to the Infinity Zone Control Owner’s Manual.Set Day, Time & Desired Humidity1. Flip down the door at the base of the Infinity Zone Controland press the BASIC button.2. Adjust the highlighted HOUR setting using the TIME(+/--) button.3. Press SCROLL button (down) to highlight MINUTE.4. Adjust the MINUTE setting using the TIME (+/--) button.5. Press SCROLL button (down) to highlight DAY.6. Adjust the current DAY setting using the TIME (+/--) but-ton.7. Press SCROLL button (down) to highlight HUMIDITY.8. Press the red HEAT button to select heating humidity.9. Adjust desired heating humidity level using either (+/--) but-ton.10. Press the blue COOL button to select cooling humidity.11. Adjust the desired cooling humidity level using ei-ther(+/--)button.12. To exit press BASIC button or close door.13. If changes are made, you will be asked to “SAVECHANGES? YES/NO.”Override Heating Schedule1. Press the red HEAT button. Heating mode is confirmedwhen the red LED next to the red HEAT button is lit.2. Use the TEMP (+/--) button to select your desired heatingtemperature.3. The default time for temporarily overriding the temperatureschedule is 2:00 HRS as indicated by the text on the lowerleft.CCUIZ01-- B