7UV Lights InstalledThis screen will appear to select whether UV lights are installed onthe system, select YES or NO, then press right--side button tocontinue.Equipment SummaryEQUIPMENT SUMMARYFURNACE 58MVB0100-12AC 24ANA136A003FILTER EACHUMIDIFIER YESUV LIGHTS YESNO YESSETUPCOMPLETE!SAVEALL SELECTIONS/NO YESA07247Fig. 20 -- Equipment SummaryThe “EQUIPMENT SUMMARY” screen will appear afterAccessories have been selected. This screen will give a summary ofall equipment automatically found or manually selected. If a wrongselection was made, press left--side button (BACK selection) to goback to that particular screen and make changes. When everythingis OK, press right--side button again to continue. (See Fig. 20.)The “SETUP COMPLETE! SAVE ALL SELECTIONS?” screenwill appear after Equipment Summary. To Save All Selectionspress (YES) right--side button. Pressing the left--side button (NOselection) will return to the Equipment Summary screen wherechanges can be performed to any of the equipment selectionscreens. After selecting YES, the initial power up sequence of thenew Infinity Control is complete.Static Pressure CheckSTATICPRESSURECHECKPLEASE WAITEXTERNAL STATICPRESSUREMEASURED:0.72 INCHESAT 1200 CFMCONTINUE >A05000Fig. 21 -- Static Pressure CheckThis screen will appear after Setup is exited. The system willperform a static pressure check. This process will take about 1 1/2minutes to complete. When completed, a screen will appeardisplaying the static pressure (in inches) across the equipment atthe expected highest delivered airflow. If the static pressure is over1 inch, a warning will appear, but equipment operation and theTrueSenset dirty filter detection operation will not be affected.NOTE: The static pressure check occurs only at initial installation,or when INSTALL is run in the INSTALL/SERVICE menu.QUICK STARTFor first time installers, Quick Start will allow a quick start up ofthe Infinity System before learning all the details of systemoperation. However, for the best possible comfort and operationrefer to the Infinity Control Owner’s Manual.Set Day, Time & Desired Humidity1. Flip down the door at the base of the Infinity Control andpress the BASIC button.2. Adjust the highlighted HOUR setting using the TIME(+/--) button.3. Press SCROLL button (down) to highlight MINUTE.4. Adjust the MINUTE setting using the TIME (+/--) button.5. Press SCROLL button (down) to highlight DAY.6. Adjust the current DAY setting using the TIME (+/--) but-ton.7. Press SCROLL button (down) to highlight HUMIDITY.8. Press the red HEAT button to select heating humidity.9. Adjust desired heating humidity level using either (+/--) but-ton.10. Press the blue COOL button to select cooling humidity.11. Adjust the desired cooling humidity level using ei-ther(+/--)button.12. To exit press BASIC button or close door.13. If changes are made, you will be asked to “SAVECHANGES? YES/NO.”Override Heating Schedule1. Press the red HEAT button. Heating mode is confirmedwhen the red LED next to the red HEAT button is lit.2. Use the TEMP (+/--) button to select your desired heatingtemperature.3. The default time for temporarily overriding the temperatureschedule is 2:00 HRS as indicated by the text on the lowerleft.NOTE: Override time will not appear if programming has beenturned off.4. You can change the temporary override time in 15--minuteincrements by pressing the TIME (+/--) button until the de-sired override time is selected, or press the HOLD buttonanytime to override the schedule indefinitely.Quick Program Schedule For All DaysThis section will give you a quick program schedule for ALLDAYS of the week. For more information on how to createcustomized schedules for every day, the entire week, or weekend,refer to the Owner’s Manual.1. Flip down the door at the bottom of the control.2. Press the SCHEDULE button, which allows you to createone schedule for the entire home.3. Press either the LEFT or RIGHT side button repeatedly (ifnecessary) until “ALLDAYS” is displayed. The WAKEtime period will be highlighted.4. Using the TIME (+/.) button, set the start time for this timeperiod.5. Press the red HEAT button. Heating temperature will beginflashing.6. Set the heating temperature using the TEMP (+/.) button.7. Press the blue COOL button. Cooling temperature will be-gin flashing.8. Set the cooling temperature using the TEMP (+/.) button.9. Set the remaining periods by using the SCROLL button toselect “DAY”, “EVENING”, and “SLEEP”.10. Exit the scheduling mode by either closing the door orpressing the SCHEDULE button.11. If changes are made, you will be asked to “SAVECHANGES YES/NO.”INSTALL / SERVICE MENUSThe “INSTALL / SERVICE” menus contain a set of vitalinformation. This information enables the Installer or Serviceperson to view a summary of what has been installed, etc. Thisinformation is not covered in the Owner’s Manual.To enter INSTALL / SERVICE menus, press and hold theADVANCED button for at least ten seconds. The following menuwill appear (See Fig. 22):CCUID01-- B