HEATING & COOUNGVisit www.carrier.cmnSYSTXCCUID01Infinity Control TMInstallation and Start-Up InstructionsInfinity Control TMSYSTXCCUID01 A03149NOTE: Read the entire instruction manual before starting theinstallation.This symbol =-> indicates a change since the last issue.TABLE OF CONTENTSSAFETY CONSIDERATIONS ..................................................... 1INTRODUCTION .......................................................................... 1INSTALLATION AND START-UP OVERVIEW ...................... 1INSTALLATION ........................................................................... 2INITIAL POWER-UP .................................................................... 5QUICK START .............................................................................. 6INSTALL / SERVICE MENUS .................................................... 7OPERATIONAL INFORMATION ............................................. 11TROUBLESHOOTING ............................................................... 12SAFETY CONSIDERATIONSRead and follow manufacturer instructions carefully. Follow alllocal electrical codes during installation. All wiring must conformto local and national electrical codes, hnproper wiring or installa-tion may damage Infinity Control System. Recognize safetyinformation. This is the safety-alert symbol Z_x • When you see thissymbol on the equipment and in the instruction manual, be alert tothe potential for personal injury. Understand the signal wordsDANGER, WARNING, and CAIfTION.These words are used with the safety-alert symbol. DANGERidentifies the most serious hazards, which will result in severepersonal injury or death. WARNING signifies a hazard, whichcould result in personal injury or death. CAUTION is used toidentify unsafe practices, which would result in minor personalinjury or product and property damage. NOTE is used to highlightsuggestions which will result in enhanced installation, reliability,or operation.INTRODUCTIONThe Infinity System consists of intelligent communicating com-ponents (User Interface, variable speed furnace or fan coil, AC orHP), which continually communicate with each other via afour-wire connection called the ABCD bus. Conventional 24-voltsignals on dedicated wires are not needed. Commands, operatingconditions, and other data are passed continually between thecomponents over the ABCD bus. The result is a new level ofcomlbrt, versatility, and simplicity.An Infinity System consists of a Infinity Control TM (themmstatplus much more) and an Infinity furnace or fan coil. All Infinityfurnaces or ban coils are variable-speed and nmlti stage formaximum flexibility, efficiency, and comlbrt. They support con-trolled ventilation, humidification, dehumidification, and air qual-ity control. Either an Infinity dual capacity (communicating), or astandard 24 vac controlled outdoor unit may be used.When using conventional outdoor units, the Infinity furnace or fancoil provides the 24 volt signals needed to control them. Also, theInfinity Network Interface Module (NIM) allows connection of aconventional HRV or ERV without the need for a separate wallcontrol.All system components are controlled through the wall mountedInfinity Control TM, which replaces the conventional thermostat andprovides the homeowner with a single wall control for all thefeatures of the system.INSTALLATION AND START-UP OVERVIEWThis instruction covers installation of the Infinity Control TM only.Physical installation instructions for the indoor, outdoor equipmentand accessories are provided with each unit.Setup, commissioning, operation, and troubleshooting of theInfinity System is covered only in this installation instruction. It isyour guide to connecting the system components and commission-ing the system once all the physical components are installed.Special screen prompts and start-up capabilities are provided in theInfinity System to simplify and lead you through the initialconnnissioning of the system. So:Install the Infinity ControV M according to this instruction.Install the indoor unit, outdoor unit, and accessories accordingto their instructions.Wire the complete system according to this instruction.Setup, commission, and operate the system according to thisinstruction to assure yourself a smooth and trouble freestart-up.Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations._m PC 101 Catalog No 809-50020 Printed in USA. Form UID01-1Sl Pg 1 01-04 Replaces: NEWisc