3Fig. 1 — 48HC**04-07 Units Model Number NomenclatureModel Series - WeatherMaker ®TC - Standard EfficiencyUnit Heat Type48 - Gas Heat Packaged RooftopCooling Tons04 = 3 tons05 = 4 tons06 = 5 tons07 = 6 tonsHeat OptionsD = Low HeatE = Medium HeatF = High HeatL = Low NOx, Low HeatM = Low NOx, Medium HeatN = Low NOx, High HeatS = Low Heat w/ Stainless Steel ExchangerR = Medium Heat w/ Stainless Steel ExchangerT = High Heat w/ Stainless Steel ExchangerSensor OptionsA = NoneB = RA Smoke DetectorC = SA Smoke DetectorD = RA + SA Smoke DetectorE = CO2F = RA Smoke Detector and CO2G = SA Smoke Detector and CO2H = RA + SA Smoke Detector and CO 2Indoor Fan Options0 = Direct Drive, Standard Static Option (04/05/06 models only)1 = Belt Drive, Standard Static Option2 = Belt Drive, Medium Static Option3 = Belt Drive, High Static OptionRefrig. Systems OptionsA = Standard One Stage Cooling ModelsB = Standard One Stage Cooling Models withHumidi-MiZer ® (07 models only)Coil Options – RTPF (Outdoor - Indoor - Hail Guard)A = Al/Cu - Al/CuB = Precoat Al/Cu - Al/CuC = E-coat Al/Cu - Al/CuD = E-coat Al/Cu - E-coat Al/CuE = Cu/Cu - Al/CuF = Cu/Cu - Cu/CuM = Al/Cu -Al/Cu — Louvered Hail GuardN = Precoat Al/Cu - Al/Cu — Louvered Hail GuardP = E-coat Al/Cu - Al/Cu — Louvered Hail GuardQ = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail GuardR = Cu/Cu - Al/Cu — Louvered Hail GuardS = Cu/Cu - Cu/Cu — Louvered Hail GuardCoil Options – Novation (Outdoor - Indoor - Hail Guard)G = Al/Al - Al/CuH = Al/Al - Cu/CuJ = Al/Al - E-coat Al/CuK = E-coat Al/Al - Al/CuL = E-coat Al/Al - E-coat Al/CuT = Al/Al - Al/Cu — Louvered Hail GuardU = Al/Al - Cu/Cu — Louvered Hail GuardV = Al/Al - E-coat Al/Cu — Louvered Hail GuardW = E-coat Al/Al - Al/Cu — Louvered Hail GuardX = E-coat Al/Al - E-coat Al/Cu — Louvered Hail GuardVoltage1 = 575/3/603 = 208-230/1/605 = 208-230/3/606 = 460/3/60Design Revision- = Factory Design RevisionBase Unit Controls0 = Electro-mechanical Controls can be used with W7212EconoMi$er ® IV (Non-Fault Detection and Diagnostic)1 = PremierLink™ Controller*2 = RTU Open Multi-Protocol Controller6 = Electro-mechanical w/ 2-Speed Fan and W7220Economizer Controller Controls. Can be used withW7220 EconoMi$er X (w/ Fault Detection & Diagnostic)Intake / Exhaust OptionsA = NoneB = Temperature Economizer w/ Barometric ReliefF = Enthalpy Economizer w/ Barometric ReliefK = 2-Position DamperU = Temperature Ultra Low Leak Economizerw/ Barometric ReliefW = Enthalpy Ultra Low Leak Economizerw/ Barometric ReliefService Options0 = None1 = Unpowered Convenience Outlet2 = Powered Convenience Outlet3 = Hinged Panels4 = Hinged Panels andUnpowered Convenience Outlet5 = Hinged Panels andPowered Convenience OutletPackaging & Seismic Complience0 = Standard1 = LTL3 = California Seismic Compliant Label4 = LTL and CA Seismic Compliant LabelElectrical OptionsA = NoneC = Non-Fused DisconnectD = Thru-The-Base ConnectionsF = Non-Fused Disconnect andThru-The-Base ConnectionsExample:Position:4 8 T C D A 0 4 A 1 A 5 - 0 A 0 A 01 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18G = 2 Speed Indoor Fan (SAV)* PremierLink ™ cannot be used with Staged Air Volume (SAV ™ )2-speed indoor fan motor.NOTES:1. On single phase (-3 voltage code) models, the following are notavailable as a factory-installed option:– Coated Coils or Cu Fin Coils– Louvered Hail Guards– Economizer or 2 Position Damper– Powered 115-volt Convenience Outlet2. Staged Air Volume (SAV ™ ) is available on size 07 only.