- 19 -3) Paper near end sensor curcuit3-1. Prepare the following parts for paper near end sensor circuit. The individual parts aresupplied from Spare parts sales department of CASIO TECNO.3-2. Mount the pin assembly 2P to the main PCB.3-3. Fix the paper near end sensor to the lower case by 2 screws and connect the sensorconnector to the main PCB.Code No. Parts Name Specification Q'ty19076948 Paper end sensor C33-651000 119030101 Adjustment screw C109302051 162366288 Sensor holder E410223B-02 119077906 Screw 3 x 8 ZMC-3 235401431 Pin assembly 2P 5045-02A 1Mount 2P Pinassembly2P connectorMain PCB1903 01011907 69481907790662366288