55Chapter 3: Commands and Programming4 Channel 4 (SONIC)5 DIG IN channelOperation ParameterThis parameter specifies the sampling unit for the Multimeter Mode.The following are the available operation parameter settings whenever Channel1 (CH1), Channel 2 (CH2), or Channel 3 (CH3) is specified by the channelselect parameter.1 Auto-IDIf Auto-ID is not activated, voltage in the range 0 to 5V is used.2 Voltage (±10V)3 Current (±10A)4 Resistance value (1k% to 100k%)5 Period (0.000004 to 50 seconds)6 Frequency (0.02Hz to 250kHz)The following are the available operation parameter settings whenever SONICis specified by the channel select parameter.1 Auto-ID2 Meters3 FeetMULTIMETER MODE SETUP ExampleThe following example takes a single data sample on Channel 1.{6,1,1,3} 6 = MULTIMETER MODE SETUP1 = Enters Multimeter Mode1 = Channel 13 = Current measurement