— 66 —(3) On the transmission unit, press [n][m][m][m][4][1][SUB TOTAL].n = number of execution. Should be within 0 to 9. If 0 or no number is input, the executioncontinues endlessly.mmm = ID number of the unit to which the data is sent.To stop the test press [ESC].Display: R/J print:0Dot/7-segment display indicates 0 only whenthe test is continued from the “Dot/7-segmentdisplay test.” When the test is performedindipendently, the dot/7-segment display indi-cates nothing.ARC–TX 41END 41ARC–TX 41peer–node:mmmARC–TX OK:xx NG:xxEND 410Associated unit’s ID number0Dot/7-segment display indicates 0 only whenthe test is continued from the “Dot/7-segmentdisplay test.” When the test is performedindipendently, the dot/7-segment display indi-cates nothing.ARC–RX 42END 42ARC–RX 42peer–node:mmmARC–RX OK:xx NG:xxEND 420Associated unit’s ID numberOperation: (1) Connect QT-2000s with ARCNET (inline) cable.(2) On the reception unit, press [n][m][m][m][4][2][SUB TOTAL].n = number of execution. Should be within 0 to 9. If 0 or no number is input, the executioncontinues endlessly.mmm = ID number of the unit from which the data is sent.To stop the test press [ESC].Display: R/J print: