Cavius 2007-003 User Manual
Developed by CAVIUS Aps Julsøvej 16, DK-8600Manufactured in P.R.C.• Place an alarm between possible fire sources and bed-rooms as minimum,• Alarms on each floor and in hallways and stairways.• Alarms in each room such as bed rooms and livingrooms.Additional alarms increase the security.Installation of alarm:1. Detach the alarm from the mounting base by twistingcounter clockwise. Use the mounting base to mark thescrew holes on the ceiling. Use the enclosed screwsand plugs to install the mounting base. Once themounting base is installed on ceiling or wall, attach thealarm by twisting clockwise.2. After mounting, test the alarm by pushing the testbutton on the top and get a loud alarm tone.Please note: The label in the product must not be removedas it contains important information regarding theproduct.The alarm may NOT be placed:• In dusty rooms• At the top of high pointed ceilings or in ceiling cornersor within 50 cm of a wall.• In rooms where the temperature goes out side +4 o to38 o C or above 90% relative humidity not condensing.• In kitchen, garage and fireplaces where damp,gases and smoke could occur. Place the alarm whereit is reachable in order to test the battery and for maintenance.Fault finding: If the smoke alarm activates withoutvisible cause, the possible cause could be:• Dust particles in the smoke chamber which can be removed by vacuuming the mesh.• High humidity condensing which can be resolved bydrying the smoke alarm.If the smoke alarm does not work when the test button ispushed, the probable cause is a faulty battery and thesmoke alarm must be replaced.Other information: Do not paint the alarm.Disposal: For product, please dispose properly at theend of life. This is electronic waste which should berecycled.Please note local regulations about information to yourinsurance company regarding installed smoke alarms..Commercial reference: 2007-003Developed by CAVIUSPLEASE READ THE USER GUIDECAREFULLY BEFORE USE ANDRETAIN FOR FUTURE USE!CAVIUS smoke alarm is designed for private homes,camping trailers and caravan installations.Technical information:Type of alarm: CAVIUS smoke alarm is a photo elec-tric smoke alarm.Alarm signal: Fire alarm condition is indicated by a seriesof repeated tones. The minimum sound level is 85 dBat 3 meters.Battery: Powered by a non-replaceable 3V CR123 Lith-ium battery with 10-year life (included).IMPORTANT: Do not replace the battery. Replacethe product if the battery fails.Low battery indicator: A short “beep” will sound andLED flash every 48 seconds when the battery is near theend of life. In this stage it will continue for a minimum30 days.It is recommended to change the smoke alarm after 10years, or if the alarm has suffered any damage. Thealarm is not active unless it is inserted in the mountingbase.Always check the alarm after inserting in the mountingbase (allow a few seconds before testing).Placement: The smoke alarm is designed for placement on aceiling or wall. The smoke alarm should be a minimum of50 cm from the wall, with a minimum of one smoke alarmper floor and a maximum distance between smoke alarmsof 10 meters.Alarm signal: The alarm has a visual and acoustic alerttone. In the passive state, the LED will flash every 48seconds to indicate normal function. In an alarming statethe LED will flash and the alarm will emit a sweepingsound pattern design to alert occupants.Hush function: In case of unintentional alarm conditionor false alarms, press the top button. This will hush thealarm for 10 minutes, after which time it will automaticallyresume its normal alarm function.Maintenance: The smoke alarm should be vacuumcleaned once per quarter, and it can be wiped with adamp cloth. (Do not open the alarm).Test the alarm at least once per quarter by pushing thetest button. The alarm will self test and give a loud alarmtone.The best places to mount the alarm:The CE mark affixed to this product confirms its com -pliance with the European Directives which apply to theproduct and, in particular, its compliance with the har-monized specifications of standard EN 14604 relating toConstruction Products Regulation 305/2011.All Rights reserved: CAVIUS Aps assumes no responsi-bility for any errors, which may appear in this manual.Furthermore, CAVIUS Aps reserves the right to alter thehardware, software, and/or specifications detailed hereinat any time without notice, and CAVIUS Aps does notmake any commitment to update the informationcontained herein. All the trademarks listed herein areowned by their respective owners. Copyright © CAVIUS Aps.EN 14604:2005 + AC :2008DoP no.: 2007-003033319MinimumMinimum 50cmfrom wallWallCeilingUKMark up screw holes with a penUse the enclosed screwsand plugs for installationSound &Test buttonMounting baseChamber filterMinimum 30cm and maximum 50cm fromceilingWallCeilingDeclared performances 4.1-4.19+5.2-5.24: PassedDownload DoP document: www.cavius.com127404 rev2 |
Related manuals for Cavius 2007-003
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine