Cavius 2106-003 User Manual
The red LED will light up to indicate that ‘LearnMode’ has been selected.Please note that when the alarms are placedin ‘Learn Mode’ they can’t be inserted into themounting base.Do not take out the battery during ‘Learn Mode’ asthis will interrupt the learn process.Press and hold the test button at one alarm only,until it beeps and the LED flashes. This alarm willbecome the master and will start sending out aspecific house code to the other alarms.As the other alarms receive the specific housecode, they will also flash the LED light.When all alarms flash the red LED, they areconnected and can be switched out of ‘LearnMode’ and installed.2. THE BEST AREAS TO INSTALL THE SMOKEALARM:• Install an alarm between possible fire sourcesand bedrooms as a minimum.• Install alarms on each floor of the house, in hall-ways and stairways.• Alarms in each room such as bed rooms andliving rooms.Additional alarms increase the security.3. AREAS WHERE NOT TO INSTALL SMOKE-ALARMS:• In dusty rooms.• At the top of a high pointed ceiling, in ceilingcorners, and within 50cm of a wall.• In rooms where the temperature goes out side+4o to 38oC or above 90% relative humidity notcondensing.• In kitchens, garages, laundries, or too close tofireplaces; areas where either dampness, gasesor smoke could occur.Place the alarm where it is reachable in order totest the battery and for maintenance.4. PLACEMENT:The smoke alarm is design to be installed on aceiling or wall.For ceiling installation:The smoke alarm should be a minimum of 50cmfrom the wall.For catheral or peak ceiling or wall installation:With a minimum of one smoke alarm per floor anda maximum distance between smoke alarms of10 meters.5. INSTALLING THE SMOKE ALARM:Detach the alarm from the mounting base bytwisting counter clockwise.Use the mounting base ring to mark the screwholes on the ceiling or the wall.Optical smoke alarm deviceCommercial reference: 2106-003Developed by CAVIUSThe smoke alarm is designed for private homes,camping trailers, mobile homes and caravans. It isnot recommended for boats.PLEASE READ THE USER GUIDECAREFULLY BEFORE INSTALLATION ANDRETAIN FOR FUTURE USE.TECHNICAL INFORMATIONThe maximum number of alarms that can be inter-linked within a house group are 32.Please note: These must be alarms from the CAVIUSThe distance between interlinked alarms dependson the house layout and they should always betested after installation. It is not advised to getmore than 10m distance between two smokealarms.Diameter: 78mm. Height: 44mmThe alarm is powered by a non-replaceable 10year battery (pack of 2 CR123A Lithium batteries).In normal situations, minimum battery life is 10years, but severe RF interferences may affectbattery life of your device.Interlinked by RF: 868 MHzComplies to standards: EN14604:2005 + AC:2008,EN300-220.1. HOW TO SET UP AND CONNECT ALARMS:Please note: The product label must not beremoved as it contains important informationregarding the product.All alarms that need to be connected in thehouse should be put into ‘Learn Mode’ by slidingthe switch on the back of the alarm to the ‘LearnMode’ position.UKMOUNTINGBASECHAMBERFILTERTEST BUTTON RED LEDLEARN MODENORMAL MODEMARK UPSCREW HOLESWITH A PENUSE THEENCLOSEDSCREWS ANDPLUGSMinimumPeak ceilingMinimum 50cmfrom peakMinimum 30cm andmaximum 50cm fromceilingWallCeilingMinimum 50cmfrom wallWallCeiling |
Related manuals for Cavius 2106-003
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine