Cavius 2208 Installation Manual
RF connection is done with the device poweredwith battery only. You do not have to connect thepower supply. The product label must not be re-moved as it contains important information re-garding the product.All alarms to be connected in the house shouldbe put into ‘Learn Mode’ by sliding the switch onthe back of the alarm to the ‘Learn Mode’ position.Please note: The learn switch placed on the backof the alarm can only be in learn position whenthe alarm is disassembled from the power supplyunit. The learn switch will automatically switch tonormal position when the alarm head is fitted tothe power supply.The red LED will light up to indicate that ‘LearnMode’ has been selected.Press and hold the test button at one alarm only,until it beeps and the LED flashes. This alarm willbecome the master and will start sending out aspecific house code to the other alarms.As the other alarms receive the specific housecode, they will also flash the LED light.When the red LED light flashes on all alarms,they are connected and MUST BE SWITCHEDOUT OF ‘LEARN MODE’ and installed.Label the original “Learn” alarm in order to easilyadd new CAVIUS Wireless Family alarms to thesystem.2. THE BEST AREAS TO INSTALL THE SMOKEALARM:• Note the local country regulations regardinginstallation.• Note the local regulations about informationto your insurance company regarding installedsmoke alarms.• Install an alarm between possible fire sourcesand bedrooms as a minimum.• Install alarms on each floor of the house, inhallways and landings.• Alarms in each room such as bedrooms andliving rooms.Additional alarms increase the security.3. AREAS WHERE NOT TO INSTALL SMOKEALARMS:• In dusty rooms• At the top of a high pointed ceiling, in ceilingcorners, and within 50cm of a wall.• In rooms where temperature goes outside therange +4o to 38°Cor above 90% relative humiditynot condensing.• In kitchens, garages, laundries, or too close tofireplaces; areas where either dampness, gasesor smoke could occur.Place the alarm where it is reachable in order totest the alarm and for maintenance.4. PLACEMENT:The smoke alarm is designed to be installed on aceiling. With a minimum of one smoke alarm perfloor and a maximum distance between smokealarms of 10 meters.For ceiling installation:The smoke alarm should be a minimum of 30cm fromthe wall.Mains powered smoke alarm deviceCommercial reference: 2208Developed by CAVIUSThe smoke alarm is designed for private homes.PLEASE READ THE INSTALLATION GUIDECAREFULLY BEFORE INSTALLATION ANDRETAIN FOR FUTURE USE.SAFETY INSTRUCTIONS:The device comes with a 3V lithium battery. Bat-teries are to be handled with care and battery pow-ered devices should be kept out of reach of chil-dren. Do not try to recharge or burn the batteries.TECHNICAL INFORMATION:Powered by a non-replaceable 3V CR123 Lith-iumbattery with 10-year life (included).It can be RF interlinked with other CAVIUSWireless Family alarms.The maximum number of alarms that can beinterlinked within a house group are 32. Pleasenote: These must be alarms from the CAVIUS Wire-less Alarm Family.The distance between interlinked alarms dependson the house layout and they should always betested after installation. It is not advised to installalarms with a separation of more than 10m.Diameter: 97mm. Height: 41mm (without mount-ing base) 52mm (with mounting base).Certified to: EN14604:2005 + AC:2008, EN300-220, EN50130-4:2011, EN60065. EN60950-1,RoHs, Reach.1. HOW TO SET UP AND CONNECT ALARMS:Start by pulling out the battery isolation strip asshown.UK1Minimum 30cmfrom wallWallCeilingCHAMBERFILTERTEST BUTTONSOUNDOUTPUTRED & GREEN LEDOpticalSiting of Optical Smoke alarmsINSTALLATION G U I D EISOLATIONSTRIPNORMAL MODE2 LEARN MODE121 |
Related manuals for Cavius 2208
manualsdatabase
Your AI-powered manual search engine