Cavius 2201-003 Quick Start Manual
to connect the power supply. The product labelmust not be removed as it contains importantinformation regarding the product.All alarms to be connected in the house shouldbe put into ‘Learn Mode’ by sliding the switch onthe back of the alarm to the ‘Learn Mode’ position.Please note: The learn switch placed on the backof the alarm can only be in learn position whenthe alarm is disassembled from the power supplyunit. The learn switch will automatically switch tonormal position when the alarm head is fitted tothe power supply.The red LED will light up to indicate that ‘LearnMode’ has been selected.Do not remove the battery during ‘Learn Mode’ asthis will interrupt the learn process.Press and hold the test button at one alarm only,until it beeps and the LED flashes. This alarm willbecome the master and will start sending out aspecific house code to the other alarms.As the other alarms receive the specific housecode, they will also flash the LED light.When all alarms flash the red LED, they areconnected and can be switched out of ‘LearnMode’ and installed.2. THE BEST AREAS TO INSTALL THE SMOKEALARM:• Note the local country regulations regardinginstallation.• Note the local regulations about informationto your insurance company regarding installedsmoke alarms.• Install an alarm between possible fire sourcesand bedrooms as a minimum.• Install alarms on each floor of the house, inhallways and stairways.• Alarms in each room such as bedrooms andliving rooms.Additional alarms increase the security.3. AREAS WHERE NOT TO INSTALL SMOKEALARMS:• In dusty rooms• At the top of a high pointed ceiling, in ceilingcorners, and within 50cm of a wall.• In rooms where temperature goes outside therange +4o to 38°Cor above 90% relative humiditynot condensing.• In kitchens, garages, laundries, or too close tofireplaces; areas where either dampness, gasesor smoke could occur.Place the alarm where it is reachable in order totest the alarm and for maintenance.4. PLACEMENT:The smoke alarm is designed to be installed ona ceiling.With a minimum of one smoke alarm per floor anda maximum distance between smoke alarms of10 meters.For ceiling installation:The smoke alarm should be a minimum of 50cmfrom the wall.For cathedral or peak ceiling:Mains powered smoke alarm deviceCommercial reference: 2201-003Developed by CAVIUSThe smoke alarm is designed for private homes.PLEASE READ THE USER GUIDECAREFULLY BEFORE INSTALLATION ANDRETAIN FOR FUTURE USE.TECHNICAL INFORMATIONThe smoke alarm is powered by mains power(110-230V AC), with a lithium back-up batteryCR2. Please note that you should only use batteriesfrom one of the following suppliers: DURACELLor HUIDERUI.It can be RF interlinked with other 2201 alarms,and with other CAVIUS Wireless Family alarms.The maximum number of alarms that can be inter-linked within a house group are 32.Please note: These must be alarms from the CAVIUSThe distance between interlinked alarms dependson the house layout and they should always betested after installation. It is not advised to installalarms with a separation of more than 10m.Diameter: 97mm. Height: 41mm (without mount-ing base) 52mm (with mounting base).Interlinked by RF: 868 MHzComplies to standards: EN14604:2005 + AC:2008,EN300-220, EN50130-4:2011, EN60065.EN60950-1, RoHs, Reach.1. HOW TO SET UP AND CONNECT ALARMS:Start by pulling out the battery isolationstrip in the battery compartmentas shown.Please note: RF connection is done with thedevice powered with battery only. You do not haveUKCHAMBERFILTEROPTIONAL HOLEFOR LAMP WIRETEST BUTTONSIREN RED & GREEN LEDISOLATIONSTRIPDO NOTREMOVE THEPRODUCT LABEL1 NORMAL MODE2 LEARN MODEMinimum112Minimum 50cmfrom wallWallCeilingPeak ceilingMinimum 50cmfrom peak |
Related manuals for Cavius 2201-003
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine