GB99IMPORTANT: if, at a later date, the control panel is fitted with atransmission module, detector/control panel recognition programmingmust be performed again for the image sequences to be transmitted.))))) “beep, test detector X,group Y, immediate”3. Check recognition programming. Press the test button on thedetector until the control panel issues the voice messagecorresponding to the selected programming.3.2 Programming for recognition by the standalone diallerFor image sequence transmission via a standalone dialler, the detectormust be programmed for recognition by the dialler.IMPORTANT• Image transmission motion detectors must be programmed forrecognition by the control panel (intrusion event management) andthe standalone dialler (image transmission).• Programming image transmission motion detectors (up to 40) to berecognised by the dialler is only possible if the alarm control panelhas been programmed for recognition by the dialler.• The number is automatically allocated by the dialler duringrecognition programming. For example, the same detector cannot beprogrammed for recognition by the control panel as number 10 andprogrammed for recognition by the dialler as number 6.• To perform recognition programming operations, the dialler must bein installation mode. When powered, the dialler is in installation mode.If a control panel has been programmed for recognition by the dialler,the dialler switches to the same mode as the control panel after 4 hwith no order being issued and automatically enters user mode.