-51-User’s ManualThis appendix guides you to set protocol, baud rate,dome address, video cable type, alarm output methodand resistor jumper.DIP Switches’ positionThe corresponding DIP-switches’ positions are shownas below,Protocol and Baud rate settingSW2 is used to set protocol and baud rate.The first six(1-6) bits of SW2 are for protocol setting and thelast two (7-8) bits are for baud rate setting. Belowchart shows the setting details. O means ON, blankmeans OFF. Default setting is 4800 bps.NOTE: If you are using AD or PHILIPS or BBVprotocol, please set the baud rate to 19200 bps.This speed dome supports multi-protocol. The settingchart is showed as below, O means ON, blank meansOFF, X means either ON or OFF. Default setting isFACTORY protocol.Appendix I: DIP Switch & Jumper Settings1 2 3 4 5 6 7 8ONSwitch Nu mber24 00bps48 00bps96 00bps19 200bpsNOTE: Protocols marked with * need otherprotocol board.FACTORYVCL ○PELCO_P ○PELCO_D ○ ○MOLYNX ○VICON ○ ○DIAMOND ○ ○KALATEL ○ ○ ○Reserved ○Reserved ○ ○Reserved ○ ○PELCO_C* ○ ○ ○Reserved ○ ○Reserved ○ ○ ○Reserved ○ ○ ○AD* ○ ○ ○ ○Reserved ○PANASONIC ○ ○Reserved ○ ○SENSORNET* ○ ○ ○Reserved ○ ○BBV* ○ ○ ○Reserved ○ ○ ○Reserved ○ ○ ○ ○Reserved ○ ○Reserved ○ ○ ○Reserved ○ ○ ○Reserved ○ ○ ○ ○Reserved ○ ○ ○Reserved ○ ○ ○ ○Reserved ○ ○ ○ ○Reserved ○ ○ ○ ○ ○PHILIPS* X X X X X ○Switch NumberProtocol1 2 3 4 5 6 7 8ONSW1 SW2SW2SW1SW2SW1