Settings via softwareService Instructions 512-211-01/532-211-01 - 00.0 - 06/2016 53E 5 1 2 USB read error Data cannot be loadedfrom USB stickCheck USB stick.Reinsert USB stick.E 5 1 3 USB write error Data cannot be copied toUSB stick.Check USB stick.Reinsert USB stick.E 5 5 0 Data write error Flash memory transfererrorSet main switch to OFF.Repeat process.Replace the mainboard.E 5 5 1 Internal processerrorSoftware error Set main switch to OFF.Repeat process.Replace the mainboard.Update software.E 770375Motor signalerrorEncoder / motor has nosignalCheck motor / encoder.E 7 3 6 Motor rotationerrorMotor stops after sometime / encoder has no sig-nalCheck motor / encoder.E 7 3 7 Error Z phase Z signal no longer changes Check motor / encoder.E 7 3 8 Error Z phase Z signal inaccurate /encoder has no signalCheck motor / encoder.E 9 0 7 Error search X-axisX-axis sensor does not res-pondSet main switch to OFF.Check sensor.E 9 0 8 Error search Y-axisY-axis sensor does not res-pondSet main switch to OFF.Check sensor.E 9 1 0 Error clamp footsearchClamp foot sensor does notrespondSet main switch to OFF.Check sensor.E 9 1 1 Error clamp footmotorClamp foot motor does notoperate correctlySet main switch to OFF.Check motor andconnection.E 9 1 2 Internal error - Notify DA ServiceE 9 1 3 Error threadcatcher searchThread catcher sensordoes not respondSet main switch to OFF.Check sensor.E 9 1 4 Error threadcatcher motorThread catcher motor doesnot operate correctlySet main switch to OFF.Check motor andconnection.Error Description Possible cause Remedy