6.5 Connecting the sewing drive to the mainsCaution:The sewing machine must be connected to the mains with a plug.Clutch motors and coupling-positioning actuators must beconnected to a 3 x 380 - 415V 50/60 Hz or 3 x 220 - 240V 50/60 Hzthree-phase supply (see tables in section 4.1).Connection takes place in accordance with connection diagram9800 169002 B or 9800 129002 B.The direct-current positioning actuator is operated with asingle-phase alternating current of 190 - 240V 50/60 Hz. Connectiontakes place in accordance with connection diagram 9800 139001 B.If it is connected to a three-phase supply of 3 x 380V, 3 x 400V or3 x 415V the sewing drive is connected to one phase and the neutralconductor.If the mains supply is three-phase 3 x 200V, 3 x 220V, 3 x 230V or 3 x240V the sewing drive is connected to two phases.If a number of direct-current positioning actuators are connected to athree-phase mains supply they should be equally distributed over allphases to avoid overloading any one of them.6.6 Drive-control connection socketsCheck the operating instructionsto see the wiring diagram.GB25B776V8..B18LSM...B2MB80EB...B41MAControl DA321G Control DAC Classic