CT-5320F/CT-5640F Fixed Thermal Camera QIG10To prepare the camera for AC/DC power connectionsAttach the male AC or DC five-pin terminal block connector to the ACor DC power cables.Figure 10: AC Power Installation Figure 11: DC Power InstallationInsert the male connector into the female connector on the back of thecamera housing.Figure 12: AC Power Cable Connections Figure 13: DC Power Cable ConnectionsPull the cables tightly back through the camera, exposing the thread ofthe cable sealing gland out of the base of the camera.Attach the electrical nut back onto the gland.Tighten the nut securely until it is finger-tight.Use the hex wrench to tighten the electrical nut to approximately8 in-lbs. (0.9 newton meters) of torque.