21, 4FG2 Cabinet/countertop depth is at discretion of customer butcabinet face MUST NOT protrude further than rear of frontpanel, see product dimensions.3 Consult local code for exact location requirements.1 Vertical to combustible surface from range grate level; ifinstalling an overhead vent hood, also check the hoodspecifications for minimum required clearances.Non-combustiblesurface alongback wallrecommended30” (762mm)Min. 136 1/2”(927mm)Max.13” (330mm)Max.4Suggestedlocation ofutilities 34 Not applicable for cabinets more than a horizontaldistance of 10” (254mm) from the edge of the range.Planning the InstallationCabinet LayoutCarefully check the location where the range is to beinstalled. For best performance, the range should be placedaway from drafts that may be caused by doors, windows andheating and air conditioning outlets.To reduce the risk of personal injury and to reduceaccumulated smoke in the room, Dacor strongly recommendsinstalling a range hood. A range hood should projecthorizontally a minimum of 5 inches beyond the face of thecabinets.All maximum and minimum dimensions and clearancesshown in the diagrams below must be maintained for safeoperation.The range may be installed flush to the rear wall.Dacor strongly recommends installing a non-combustiblematerial on the rear wall above the range and up to the venthood or installation of a backguard. It is not necessary toinstall non-combustible materials behind the range below thecountertop height.Any openings in the wall behind the appliance or in the floorunderneath it must be sealed.•••••CUT-OUT DIMENSIONSRange Model F G HER36D 42” (1067mm)*36” (914mm)**36 1/16”(916mm)**33 ½”(848mm)ER48D 54” (1372mm)*48” (1219mm)**48 1/16”(1221mm)**43 ½”(1102mm)* Recommended **MinimumAll tolerances: +1/16”, -0 (+1.6mm, -0)Unless otherwise statedGas and Electrical ServiceThe shaded area shown denotes the location of the gasinlet and the electrical junction box/receptacle. This is therecommended location. For replacement purposes, thelocation of the existing utilities may be utilized provided theydo not interfere with the sides or rear of the range. Checklocal building codes for permissible gas valve locations.An external manual shut-off valve must be installed betweenthe gas inlet and the range, for the purpose of turning on orshutting off gas to the appliance.The installation must allow for the following:Access to the gas shut-off valve when the unit is installed.Access to the remote circuit breaker panel/fuse box, when therange is in place.The gas supply piping and shut-off valve, and the electricaljunction box/receptacle must be located so they do notinterfere with the range when it is installed.The junction box and gas shut off valve must be locatedso that the range can be pulled out for service while theappliance remains connected.••••••G10" (254 mm) Min.to combustible sidewalls above the range(both sides)non-combustibleMinumum Countertop Height:30 1/4” (768 mm)Maximum Countertop Height:36 1/2” (927 mm)rear wall recommendedBacksplash3/8" (10 mm)Min. flat countertopoverhangH2 13/16"(71.4 mm)3Cutout with Optional ERv Raised vent (Top view)Standard Cutout withRange HoodAPPROVED RAISED VENT MODEL NUMBERSRange Model ERV Raised Vent ModelER36D ERV36-ERER48D ERV48-ERIMPORTANT: See the raised vent installation instructionsfor the duct and electrical installation requirements. Useonly the raised vent models specified below.