Earthing 286other monitor devices, please use the copper resistance soft cable and its section shall bemore than 4mm2. The monitor system usually can adopt the one-point ground. Please connect the ground end of 3-pin socket in the monitor system to the ground port ofthe system (protection ground cable)Appendix 7.4 The Shortcut Way to Check the ElectricSystem by Digital MultimeterFor 220V AC socket, from the top to the bottom, E (ground cable), N (neutral cable), L(livecable). Please refer to the following figure.There is a shortcut way to check these thee cables connection are standard or not (not theaccurate check).In the following operations, the multimeter range shall be at 750V.For E (earth cable)Turn the digital multimeter to 750V AC, use your one hand to hold the metal end, and then theother hand insert the pen to the E port of the socket. See the following figure. If the multimetershows 0, then you can see current earth cable connection is standard. If the value is more than10, then you can know there is inductive current and the earth cable connection is not proper.